搜档网
当前位置:搜档网 › SUN SL500 磁带库 配件PN

SUN SL500 磁带库 配件PN

SUN SL500 磁带库 配件PN
SUN SL500 磁带库 配件PN

Drive Capable) SL50001-0000 (T) SL500 MODULAR LIBRARY SYSTEM

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-LV05 (T) LVD SCSI INTERFACE

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-IFC2 (T) NATIVE 2GB FIBRE INTERFACE

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-RMPS (T) REDUNDANT POWER SUPPLY

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-UP20 (T) 30 TO 50 CART SLOT UPGRADE

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-UP50 (T) 50 TO 100 CART UPG W/4 DR BAYS

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-UR50 (T) 50 TO 100 CART UPG W/RMPS

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-1DES (T) 1X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-2DES (T) 2X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-3DES (T) 3X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-4DES (T) 4X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-1DER (T) 1X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-2DER (T) 2X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-3DER (T) 3X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-4DER (T) 4X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots / 2 Drive Capable) SL50001-EURO

EUR, F/IEC 320

SL500 Tape Library

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-0000 (T) SL500 MODULAR LIB SYS LTO LVD

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-LV05 (T) LVD SCSI INTERFACE

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-RMPS (T) REDUNDANT POWER SUPPLY

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-UP20 (T) 30 TO 50 CART SLOT UPGRADE

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-UP50 (T) 50 TO 100 CART UPG W/4 DR BAYS

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-UR50 (T) 50 TO 100 CART UPG W/RMPS

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-1DES (T) 1X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-2DES (T) 2X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-3DES (T) 3X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-4DES (T) 4X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-1DER (T) 1X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-2DER (T) 2X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-3DER (T) 3X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-4DER (T) 4X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 SCSI Drive) SL50002-EURO EU R, F/IEC 320

SL500 Tape Library

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-0000 (T) SL500 MODULAR LIB SYS LTO FC

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-IFC2 (T) NATIVE 2GB FIBRE INTERFACE

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-RMPS (T) REDUNDANT POWER SUPPLY

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-UP20 (T) 30 TO 50 CART SLOT UPGRADE

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-UP50 (T) 50 TO 100 CART UPG W/4 DR BAYS

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-UR50 (T) 50 TO 100 CART UPG W/RMPS

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-1DES (T) 1X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-2DES (T) 2X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-3DES (T) 3X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-4DES (T) 4X 8U DR EXPAN MOD SGL PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-1DER (T) 1X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-2DER (T) 2X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-3DER (T) 3X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-4DER (T)

4X 8U DR EXPAN MOD REDUND PWR

SL500 Tape Library SL500 Tape Library (30 Slots w 2 FC Drive) SL50003-EURO EUR, F/IEC 320

SL500 Tape Library Tape Drives

SL500 Tape Library SL500 Tape Library Tape Drives LTO2S50-0000 (T) LTO GEN2 DRI VE FOR SL500

SL500 Tape Library SL500 Tape Library Tape Drives LTO2S50-HPFC (T) HP LTO FIBRE INTERFACE

SL500 Tape Library SL500 Tape Library Tape Drives LTO2S50-HPLV (T) HP LTO LVD I NTERFACE

SL500 Tape Library SL500 Tape Library Tape Drives LTO2S50-IBFC (T) IBM LTO FIBR E INTERFACE

SL500 Tape Library SL500 Tape Library Tape Drives LTO2S50-IBLV (T) IBM LTO LVD INTERFACE

SL500 Tape Library SL500 Tape Library Tape Drives LTO2AS4-0000 (T) AS400 LTO GE N2 FC DRIVE

SL500 Tape Library SL500 Tape Library Tape Drives LTO2AS4-TXS5 (T) SL500 DRIVE TRAY

StorageTek SL500 Tape Library - SCSI LVD

StorageTek SL500 Modular Library System E SCSI LVD. SL50E01-002.

StorageTek SL500 Tape Library - FC

StorageTek SL500 Modular Library System E Fibre Channel. SL50E01-001.

StorageTek SL500 Tape Library - SCSI LVD - 50 Slot

StorageTek SL500 Modular Library System E SCSI LVD, 50 slot. SL50E01-004. StorageTek SL500 Tape Library - FC - 50 Slot

StorageTek SL500 Modular Library System E Fibre Channel, 50 slot. SL50E01-003.

StorageTek SL500 Tape Library - SCSI LVD - (2) LTO3

StorageTek SL500 Modular Library System with (2) HP LTO3 SCSI LVD E. SL50E32-00 1.

StorageTek SL500 Tape Library - SCSI LVD - (2) LTO3

StorageTek SL500 Modular Library System with (2) HP LTO3 SCSI LVD E, 50 Slot. S L50E32-002.

StorageTek SL500 Tape Library - FC - (2) LTO3

StorageTek SL500 Modular Library System with (2) HP LTO3 Fibre Channel E. SL50E 33-001.

StorageTek SL500 Tape Library - FC - (2) LTO3

StorageTek SL500 Modular Library System with (2) HP LTO3 Fibre Channel E, 50 Sl ot. SL50E33-002.

StorageTek SL500 tape library - 30 slots - SCSI interface.

Sun StorageTek SL500 tape library base module with 30 slots and SCSI interface. STK Part # SL50E01-002. Sun Part # SL500-30-SCSI-Z

StorageTek SL500 tape library - 24 slots - SCSI interface - LTO/SDLT support Sun StorageTek SL500 tape library, mixed media version (LTO/SDLT support), base module with 24 slots, SCSI interface. STK Part # SL50M01-003. Sun Part # SL500 MM-24-SC-Z

StorageTek SL500 tape library - 24 slots - FC interface - LTO/SDLT support Sun StorageTek SL500 tape library, mixed media version (LTO/SDLT support), base module with 24 slots, FC interface. STK Part # SL50M01-001. Sun Part # SL500MM -24-FC-Z

StorageTek SL500 tape library - 30 slots - FC interface

Sun StorageTek SL500 tape library base module with 30 slots and FC interface. S TK Part # SL50E01-001. Sun Part # SL500-30-FC-Z

StorageTek SL500 tape library - 50 slots - SCSI interface

Sun StorageTek SL500 tape library base module with 50 slots and SCSI interface. STK Part # SL50E01-004. Sun Part # SL500-50-SCSI-Z

StorageTek SL500 tape library - 42 slots - SCSI interface - LTO/SDLT support Sun StorageTek SL500 tape library, mixed media version (LTO/SDLT support), base module with 42 slots, SCSI interface. STK Part # SL50M01-004. Sun Part # SL500 MM-42-SC-Z

StorageTek SL500 tape library - 50 slots - FC interface

Sun StorageTek SL500 tape library base module with 50 slots and FC interface. S TK Part # SL50E01-003. Sun Part # SL500-50-FC-Z

StorageTek SL500 tape library - 42 slots - FC interface - LTO/SDLT support Sun StorageTek SL500 tape library, mixed media version (LTO/SDLT support), base

module with 42 slots, FC interface. STK Part # SL50M01-002. Sun Part # SL500MM -42-FC-Z

StorageTek SL500 tape library - 30 slots with 2 HP LTO3 SCSI drives

Sun StorageTek SL500 tape library bundle, 30 slots base module (SCSI interface) with 2 HP LTO3 SCSI drives. STK Part # SL50E32-001. Sun Part # SL500-2L3-30-SC -Z

StorageTek SL500 tape library - 50 slots with 2 HP LTO3 SCSI drives

Sun StorageTek SL500 tape library bundle, 50 slots base module (SCSI interface) with 2 HP LTO3 SCSI drives. STK Part # SL50E32-002. Sun Part # SL500-2L3-50-SC -Z

StorageTek SL500 tape library - 30 slots with 2 HP LTO3 4Gb FC drives

Sun StorageTek SL500 tape library bundle, 30 slots base module (FC interface) w ith 2 HP LTO3 4Gb FC drives. STK Part # SL50E33-001. Sun Part # SL500-2L34-30FC -Z

StorageTek SL500 tape library - 50 slots with 2 HP LTO3 4Gb FC drives

Sun StorageTek SL500 tape library bundle, 50 slots base module (FC interface) w ith 2 HP LTO3 4Gb FC drives. STK Part # SL50E33-002. Sun Part # SL500-2L34-50FC -Z

StorageTek SL500 tape library - 30 slots with 2 IBM LTO4 4GB FC Drives

Sun StorageTek SL500 tape library, 30 slots base module (FC interface) with 2 I BM LTO4 4GB FC Drives. Sun Part # SL500-30L4IB4GFZ

StorageTek SL500 tape library - 30 slots with 2 HP LTO3 2GB FC drives

Sun StorageTek SL500 tape library bundle, 30 slots base module (FC interface) w ith 2 HP LTO3 2GB FC drives. STK Part # SL50E33-001. Sun Part # SL500-2L3-30-FC -Z

StorageTek SL500 tape library - 50 slots with 2 IBM LTO4 4GB FC Drives

Sun StorageTek SL500 tape library, 50 slots base module (FC interface) with 2 I BM LTO4 4GB FC Drives. Sun Part # SL500-50L4IB4GFZ

StorageTek SL500 tape library - 50 slots with 2 HP LTO3 2GB FC drives

Sun StorageTek SL500 tape library bundle, 50 slots base module (FC interface) w ith 2 HP LTO3 2GB FC drives. STK Part # SL50E33-002. Sun Part # SL500-2L3-50-FC -

昆腾磁带库日常操作、维护及故障诊断指南

金宏工程存储备份 昆腾磁带库 日常操作、维护及故障诊断手册 同方股份有限公司 2007年6月1日

1.日常管理和维护 主要操作介绍 2. 昆腾磁带库PX系列快速配置说明 3.1 SCALAR快速设置 SCALAR的配置有两种方法: 1、通过OCP控制面板设置。 2、通过WEB CLIENT方式。 两种方式的管理员都是ADMIN,密码是PASSWORD。我们推荐使用第二种方式,要使用第二种方式,必须通过OCP控制面板事先设置好IP地址、子网掩码、网关。同时必须满足以下条件: 1、Internet Explorer6.0以上 2、JAVA1.4以上 SCALAR磁带库按照说明书正确连接好电缆,加电,自检通过后,呈现如下面图片所示界面,根据下面的界面提示设置好时间、IP地址等相关设置。 图3-1 图3-2

图3-3 图3-4 图3-5 图3-6 注意:在该画面一定要选择Remote,否则,将不能通过WEB方式配置。图3-7

如图3-7所示,按OK结束。这样可以通过WEB界面来配置SCALAR I500磁带库。 3.2 SCALAR配置(WEB方式) 打开Internet Explorer ,输入HTTP://磁带库IP ADDRESS,按提示进入帐号和口令。 既可开始设置。 步骤如下: 1、进行全局设置,此向导可进行时间设置、LICENSE许可密匙输入(图3-2)(默认已输入,扩展时需要),CLEANING SLOT设置(图3-3,3-4),I/E设置(图3-5),PARTITIONING设置(3-6)。 图3-1 图3 -2

图3-3 图3-4

手把手教你安装TS3310磁带库

手把手教你安装IBM TS3310磁带库(一) 一、产品简述 TS3310 磁带机性能强大、容量大并且可靠,能够满足磁带存储的巨大要求。该磁带库模块化程度高且可伸缩性强,从基本磁带库5U控制模块,直到每个配置均是9U的附加扩展单元都在可伸缩范围内。LTO3的磁带驱动器可以读写原始LTO2数据磁带盒并读取LTO1数据磁带盒。 TS3310磁带库包含磁带库控制模块,固定盒式磁带存储器(30个插槽)、I/O 站(6个插槽)、触摸显示屏、磁带盒处理自动装置以及最多两个LTO 3磁带机。 您可以将多达4个可选扩展模块添加到控制模块。每个L9U扩展模块可以容纳最多4个LTO3磁带机和最多80个盒式磁带插槽,以及12个可配置I/O站插槽。 该磁带库支持带有LVD Ultra160 SCSI或本机交换光纤通道连接的LTO3磁带机,从而能够与许多开放式系统服务器连接。 1. 前面板组件展示

1 存取口 2 电源按钮 3 绿色供电(液晶指示灯) 4 琥珀色操作员干预警报指示灯 5 操作员面板(触摸式) 6 5U控制模块 7 I/O站 8 9U扩展模块 I/O站 I/O站位于磁带库的前面板上,它将在不干扰正常磁带库操作的前提下实现磁带盒的导入和导出,一个控制模块I/O站的容量为6个磁带盒,一个9U扩展模块 I/O站的容量为12个磁带盒。

注: 此磁带库会读取条形码标签以确定每个插槽中的特定磁带盒,请确保磁带库中的所有磁带盒都有适当的条形码标签。 将I/O站插槽分配给逻辑磁带库时,只有该逻辑磁带库才能访问此插槽。I/O站将由所有逻辑磁带库共享,但是I/O站插槽一次只能被一个逻辑磁带库占用。 2. 后面板组件展示 1 控制模块(L5B) 2 扩展模块(E9U) 3 控制模块磁带机(显示FC磁带机) 4 扩展模块磁带机 5 电源控制器 6 控制模块与扩展模块的连接线 7 客户用网络端口(4端口提供) 8 WEB方式管理磁带库接口(RJ45)

VTL软件安装及配置指南

浪潮虚拟磁带库VTL1000软件安装指南 1.硬件平台及软件要求 硬件平台为AS500N,前两个盘位做RAID1,安装CentOS4.0 Update2 X86_64系统。 Raid1大小为470000M 安装CentOS时,具体的分区情况为: boot 239988M / 222000M Swap 8000M CentOS必选包为 Xwindows System GNOME Desttop Environment Applications: Editors Servers: Server Configuration Tools Mail Server DNS Name Server Postgre SQL Database Network Server(iscsi-initiator软件包) Development Development Tools System Administrator Tools System Tools(sysstat软件包) Campatibility Arch Support 安装完CentOS后重新引导并进入系统 !!设置系统root帐号的密码为root 2.VTL软件安装 将VTL4.0软件光盘放入光驱,挂载光盘 #mount /dev/cdrom /mnt

2.1.安装VTL 软件默认的安装目录时/usr/local/vtl,安装日志存放在/usr/local/vtl-archive下,在此文件目录下,vtlinstall-26Jan08-222434.log 即为安装过程记录文档,如果需要查看安装过称,可以用命令#less vtlinstall-26Jan08-222434.log查看。 #cd /mnt #sh vtlinstall 当出现如下时,输入Y,并按回车继续安装。 出现输入Luns数时,如图,键入16或是32,即设定磁盘划16或是32个lun 当出现如下图示时,默认选择回车继续,表示此文件系统只有一个。

昆腾Quantum Scalar i40-i80维护手册

第1章昆腾Quantum Scalar i40/i80维护 手册 1.1.1关机 操作面板选择Actions > Shutdown > Shutdown Library Web客户端选择Operations > System Shutdown. 当操作面板出现关机提示,如下图: 按下前面电源键 1.1.2重启带库 操作面板选择Actions > Shutdown >Restart Library Web客户端选择Operations > System Shutdown> Restart 1.1.3解锁I/E槽 操作面板选择Actions > I/E > Unlock I/E Station Web客户端选择Operations > I/E Station Unlock 1.1.4释放磁带抽屉

操作面板选择Actions >Magazine > Release Web客户端选择Operations >Release Magazine 1.1.5导入磁带 通过操作面板: 通过前面板只能一次导入一盘磁带 1 选择 Actions > Import Tape. 2 选择要将磁带导入的分区 3 用上、下按钮选择一盘磁带导入 4 选择 Import. 磁带将会被导入到分区的第一个空槽位中 1.1.6批量导入磁带 1 通过web客户端选择Reports > Library Configuration查看带库的槽位分配 2 操作面板选择Actions >Magazine > Release Web客户端选择Operations >Release Magazine 释放磁带抽屉 3 将磁带放在存储槽位中 1.1.7移动磁带 移动磁带只能通过web客户端 1 选择 Operations > Media > Move. 2 如果多于一个分区存在,请选择需要移动磁带的分区

centos6.5+mhvtl+gui+iscsi-tgt虚拟磁带库的安装与应用

一.Mhvtl+mhvtl gui+iscsi 1.安装: yum install lsscsi mt-st mtx zlib-devel sg3_utils zlib lzo-devel kernel-devel kernel-headers gcc 接着创建vtl用户: #useradd vtl #passwd vtl #mkdir /opt/mhvtl # mkdir /etc/mhvtl # chown -Rf vtl:vtl /opt/mhvtl #chown -Rf vtl:vtl /etc/mhvtl (/etc/mhvtl为配置文件路径/opt/mhvtl为虚拟带库存储路径) 2. 编译安装 MHVLT # tar -zxvf mhvtl-2013-03-22.tgz [rootcentos001 tool]# cd mhvtl-1.4 [rootcentos001 mhvtl-1.4]# cd kernel [rootcentos001 kernel]# make;make install [rootcentos001 mhvtl-1.4]# make;make install 如果未安装lzo和lzo-devel开发环境将收到如下报错: Note: Since mhvtl-1.3, both lzo and zlib are required to build vtltape Typical error (missing lzo devel package) looks like: cc -Wall -Wshadow -g -O2 -D_LARGEFILE64_SOURCE -I../kernel -DMHVTL_VERSION=\"1.4.0\" -DMHVTL_DEBUG -DUSR=\"vtl\" -DMHVTL_HOME_PATH=\"/opt/mhvtl\" -DMHVTL_CONFIG_PATH=\"/etc/mhvtl\" -c -o vtltape.o vtltape.c vtltape.c:92:25:error: lzo/lzoconf.h: No such file or directory vtltape.c:93:23: error: lzo/lzo1x.h: No such file or directory vtltape.c: In function 'uncompress_lzo_block' [rootcentos001 mhvtl-1.4]# service mhvtl status Could not locate library config file: /etc/mhvtl/library_contents.10 Creating a default one Please stop mhvtl & edit /etc/mhvtl/library_contents.10 to suit your requirements Could not locate library config file: /etc/mhvtl/library_contents.30 Creating a default one Please stop mhvtl & edit /etc/mhvtl/library_contents.30 to suit your requirements Usage: /etc/init.d/mhvtl {start|stop|shutdown} [rootcentos001 mhvtl-1.4]# service mhvtl start vtllibrary process PID is 1729 vtllibrary process PID is 1733 查看虚拟带库状态信息 [rootcentos001 mhvtl-1.4]# lsscsi -g

HP MSL4080磁带机安装配置

HP MSL 磁带机安装配置 一:备份架构 二:主机准备 1:根据磁带机类型准备备份服务器需要SCSI HBA卡或者FC HBA卡 2:4GB FC HBA卡需要LTO4 ;8GB HBA卡需要LTO5 Master/media 网 卡 HBA 卡 LAN MSL 网 卡 HBA 卡 生产服务器

三:设备安装1:移除磁带库锁 2:设备上架

3:连接FC线缆 四:配置设备 1:设备管理密码 通过OCP(操作面板)设置管理员密码(见下文)2:设置日期和时间 3: 配置网络 默认情况下设备IP有DHCP自动分发,修改为静态IP 4:配置光纤(SCSI)端口 建议采用默认配置

五:设备连接 1:安装备份软件或者驱动 2:确认主机和磁带库连接 :安装HP tapetools(诊断工具) 确定主机操作系统:settings—control panel—system—hardware—device manager—tape drive and/or media change 六:检查固件版本 MSL2024 OCP 1. From the Home screen, press Next until the display shows Status/Information. Press Enter. 2. Press Next until the display shows Library Information. Press Enter. 3. Press Next until the display shows the Firmware Rev. MSL4048, MSL8048, and MSL8096 (OCP) 1. Use the control keys to navigate to Info > Identity > Library. 2. The Library Controller FW Revision field shows the Library firmware revision.

在AIX下通过光纤连接LTO 3582磁带库及驱动的安装方法

在AIX下通过光纤连接LTO 3582磁带库,驱动的安装方法 环境 本测试的硬件环境如下: F80, 操作系统为AIX 5.1,安装了光纤接口卡(HBA)6227 LTO 磁带机,3582-L23 本测试的软件环境如下: oslevel: 5.1.0.0 Maintenance level(instfix -ik |grep ML) # instfix -ik |grep ML instfix: A flag requires a parameter: k All filesets for 5.0.0.0_AIX_ML were found. All filesets for 5.1.0.0_AIX_ML were found. All filesets for 5.1.0.0_AIX_ML were found. All filesets for 5100-01_AIX_ML were found. All filesets for 5100-02_AIX_ML were found. All filesets for 5100-03_AIX_ML were found. Not all filesets for 5100-04_AIX_ML were found. 6227 HBA 卡的微码版本应高于S1F3.22A0 # lscfg -vl fcs0 DEVICE LOCATION DESCRIPTION fcs0 27-08 FC Adapter Part Number.................09P1162 EC Level....................D Serial Number...............KT04802590 Manufacturer. (0010) FRU Number..................09P1173 Network Address.............10000000C925121E ROS Level and ID (02903291) Device Specific.(Z0)........4002206D Device Specific.(Z1) (10020193) Device Specific.(Z2)........3001506D Device Specific.(Z3) (02000909) Device Specific.(Z4)........FF101450 Device Specific.(Z5) (02903291) Device Specific.(Z6) (06113291) Device Specific.(Z7) (07113291) Device Specific.(Z8)........20000000C925121E Device Specific.(Z9)........SS3.22A1 Device Specific.(ZA)........S1F3.22A1

HP-MSL4080磁带机安装配置

HP MSL 磁带机安装配置一:备份架构 二:主机准备 1:根据磁带机类型准备备份服务器需要SCSI HBA卡或者FC HBA卡 2:4GB FC HBA卡需要LTO4 ;8GB HBA卡需要LTO5 Master/media 网 卡 HBA 卡 LAN MSL 网 卡 HBA 卡 生产服务器

三:设备安装1:移除磁带库锁 2:设备上架

3:连接FC线缆 四:配置设备 1:设备管理密码 通过OCP(操作面板)设置管理员密码(见下文) 2:设置日期和时间 3: 配置网络 默认情况下设备IP有DHCP自动分发,修改为静态IP 4:配置光纤(SCSI)端口 建议采用默认配置

五:设备连接 1:安装备份软件或者驱动 2:确认主机和磁带库连接 :安装HP tapetools(诊断工具) 确定主机操作系统:settings—control panel—system—hardware—device manager—tape drive and/or media change 六:检查固件版本 MSL2024 OCP 1. From the Home screen, press Next until the display shows Status/Information. Press Enter. 2. Press Next until the display shows Library Information. Press Enter. 3. Press Next until the display shows the Firmware Rev. MSL4048, MSL8048, and MSL8096 (OCP) 1. Use the control keys to navigate to Info > Identity > Library. 2. The Library Controller FW Revision field shows the Library firmware revision.

容错虚拟磁带库软件自行安装说明

容错虚拟磁带库软件自行安装说明 说明:容错公司提供的是虚拟磁带库软硬件一体产品,但会提供最新的测试版本软件供合作伙伴进行功能测试,测试版本并不保证在任何的硬件配置机器上能成功安装和配置,如需要高级支持,请联系容错技术人员(400-666-3436), 安装配置步骤如下: 一、安装CentOS 5.4 操作系统: 1.下载CentOS 5.4 64位操作系统 2.安装CentOS,安装时把系统全部安装在单独的硬盘上(准备用作系统的盘),其他 都默认。 3.安装完成配置一下IP地址和主机名称。 二、安装RongCuo VTL System内核: 4.先装libXp-1.0.0-8.1.el 5.i38 6.rpm和mod_auth_pam-1.1.1-6.el5.x86_64.rpm # rpm -ihv libXp-1.0.0-8.1.el5.i386.rpm # rpm -ihv mod_auth_pam-1.1.1-6.el5.x86_64.rpm 5.完成后再装kernel-2. 6.29-rcbox.x86_64.rpm # rpm -ihv kernel-2.6.29-rcbox.x86_64.rpm 6.装完kernel,执行post-ker-rcbox.sh脚本 # ./post-ker-rcbox.sh 7.重启机器 # shutdown -h now 三、安装RongCuo VTL软件: 8.解压ftsvtl-b603-20110524.tar.gz # tar -vxzf ftsvtl-b603-20110524.tar.gz

#./install.sh (全程默认安装) 9.启动ftsvtl服务器:service ftsvtl start (或者重启机器) 10.卸载ftsvtl: # /opt/ftsvtl/uninstall 四、为Enable FC Target初始化VTL System环境: (修改的启动image为:/boot/initrd-2.6.29-rcbox.img) 11.使系统启动时用RongCuo FC 驱动(含有Target)ql2300_fw.bin和ql2400_fw.bin驱动 QLogic FC卡 a.复制ql2300_fw.bin和ql2400_fw.bin到系统 # cp ql2400_fw.bin /lib/firmware # cp ql2300_fw.bin /lib/firmware b.删除或者改名系统自带的qla2xxx.ko和qla4xxx.ko # mv /lib/modules/2.6.29-rcbox/kernel/drivers/scsi/qla2xxx/qla2xxx.ko /lib/modules/2.6.29-rcbox/kernel/drivers/scsi/qla2xxx/qla2xxx_bk.ko # mv /lib/modules/2.6.29-rcbox/kernel/drivers/scsi/qla4xxx/qla4xxx.ko /lib/modules/2.6.29-rcbox/kernel/drivers/scsi/qla4xxx/qla4xxx_bk.ko 12.修改启动时的image:/bootinitrd-2.6.29-rcbox.img c.解压原有的image: # cd /boot # cp initrd-2.6.29-rcbox.img /tmp/initrd-2.6.29-rcbox.img.gz # cd /tmp # gunzip initrd-2.6.29-rcbox.img.gz # mkdir newinitrd # mv initrd-2.6.29-rcbox.img newinitrd # cd newinitrd # cpio -ivmd < initrd-2.6.29-rcbox.img

TS用户安装手册

TS3310用户安装手册

目录 TS3310用户安装手册 (1) 前言 (3) 一、硬件安装 (4) (一) 前面板组件 (4) (二) 后面板组成模块 (5) (三) 内部组件 (6) 1. 存储仓 (6) 2. 机械臂 (6) (四) 在机架中安装新磁带库 (6) 1. 卸下用于保护拾取器组合件的所有内部包装材料 (7) 2. 除去塑料带 (8) 3. 从I/O站的箱上除去黄色带状包装条 (8) 4. 再次确认下所拿下的塑料带及固定带。 (9) 5. 减轻重量 (9) 6. 准备用于安装的磁带库模块 (10) 7. 在机架中安装底部磁带库模块 (13) 8. 安装磁带库配置中的其他模块,这里以安装控制模块为例。 (15) 9. 连接线缆 (17) 二、管理带库 (18) (一) 开关机顺序 (18) 1. 开机 (18) 2. 关机 (18) (二) 用户界面 (19) (三) 操作员面板 (19) 1. 公共操作员面板元素 (20) 2. 公共标题元素 (20) 3. 操作员面板提供的菜单 (21) (三) web用户界面 (23) (四) 初始化带库 (24) 1. 配置TS3310的清洗带槽位 (24) 2. 添加机器臂的控制路径 (25) (五) 日常操作 (26) 1. 查看系统信息 (26) 2. 查看带库map (26) 3. 添加数据带 (26) 4. 取出数据带 (27) 5. 移动数据带 (27) 6. 添加清洗带 (27) 7. 取出清洗带 (27) 8. 清洗驱动器 (28) 9. 查看error信息 (28) 10. 添加License (28)

NBU磁带库备份系统的安装步骤

软件安装 软件安装主要包括MasterServer、MediaServer、软件的安装。在备份系统中,选择hp做为MasterServer,同时充当MediaServer的角色。为便于管理,确定MasterServer作备份系统的Global Database Host,用于存放所有的配置和备份信息。下面逐一介绍每一种软件的安装过程,软件安装列表见附件三。 2.4.1 NetBackup DataCenter MasterServer Installition 安装前作如下准备工作,在MediaServer安装时也要作同样的准备:·连接硬件 所有MediaServer/MasterServer以及带库、磁带机均连接到一台SAN 光纤交换机。 ·硬件识别 在安装软件之前,要保证系统能够识别磁带机和机械手(只需 MasterServer识别机械手) #ioscan –fnC tape ·系统空间 安装MasterServer之前,确保系统空间大小: RAM ≥512Mb 安装目录可用空间≥64Mb /tmp可用空间≥32Mb ·系统配置 在备份环境中每台主机都要修改/etc/hosts文件,提供hostname/ip的 解析。在MasterServer端的/etc/hosts文件中增加如下内容: 安装步骤如下: step1: pfs_mountd & pfsd 6& pfs_mount -o xlat=unix /dev/dsk/c3t2d0 /cdrom step2:切换到光盘目录 #cd /cdrom step3:执行安装脚本 #./install VERITAS Installation Script Copyright 1993 - 2002 VERITAS Software Corporation, All Rights Reserved.

SUN服务器磁带机数据库安装及日常维护手册

SUN硬件系统安装及管理维护手册 目录 一,Sun X4600服务器安装及维护 (3) 1.1 X4600服务器硬件设置及维护管理 (3) 1.2在X4600服务器上安装RHEL5.2操作系统 (7) 二,Sun STK6140存储阵列安装及维护 (16) 2.1 STK6140磁盘阵列硬件安装 (16) 2.2 STK6140磁盘阵列管理与维护设置 (17) 三,SUN SL48自动磁带库安装及维护 (25) 3.1 SL48磁带库安装 (25) 3.2 SL48维护管理设定 (26)

四,Oracle 10g数据库安装 (28) 4.1 安装基本信息 (28) 4.2 安装前准备工作 (28) 4.3 安装ORACLE 10G (10.2.0.1版本)数据库系统 (31) 五,VCS双机热备软件安装及日常维护 (41) 5.1 VCS 5.0双机热备软件安装 (41) 5.2 VCS软件日常管理 (43) 六,NETBACKUP自动备份软件安装及日常维护 (48) 6.1 NETBACKUP备份软件安装 (48) 6.2 Netbackup软件日常管理 (55) 七,系统开关机流程 (57) 7.1系统关机流程 (57) 7.2 系统开机流程 (57)

一Sun X4600服务器安装及维护 1.1 X4600服务器硬件设置及维护管理 SUN X4600服务器背后示意图: 服务器连接方式: SUN X4600服务器有二种人机界面连接方式: 显示器/键盘/鼠标管理 ILOM管理(有串行口和网络口两种管理途径) 各接口部位如上图所示,对于支持无显示器操作的操作系统,键盘、 鼠标和视频显示器是可选件。安装在机柜中的服务器,可以采用网络 管理口进行远程管理。 网络管理IP设置: 如上图所示,标注"NET 0" 至"NET 3" 的连接器为10/100/1000 千兆位以太网端口。标注"NET MGT" (网络管理)的端口为10/100 以太网端口,用于将系统连接到一个管理网络。设置方法如下: 使用串行电缆连接到ILOM,通过笔记本或者PC机上的串口通信接口和串口通讯程序(例如:XP的超级终端,Secure CRT等), 连接到ILOM的串行管理口,连接参数设置为:

磁带库通用技术规范

磁带库 通用技术规范

磁带库 采购标准规范使用说明 1. 本标准规范作为国家电网公司磁带库通用物资采购的统一技术规范书,由通用部分、专用部分、投标人响应和使用说明等四个部分组成,适用用于国家电网公司磁带库通用物资集中采购采购。 2. 通用部分包括一般性技术条款,原则上不需要项目招标人(项目单位)填写,不能随意更改。如通用部分相关条款确实需要改动,项目单位应填写《通用部分技术条款\技术参数变更表》并加盖该网、省公司物资采购管理部门的公章,及辅助说明文件随招标计划一起提交至招标文件审查会。经标书审查同意后,对通用部分的修改形成《技术通用部分条款变更表》,放入专用部分中,随招标文件同时发出并视为有效。 3. 本标准规范的专用部分主要包含货物需求及供货范围一览表、必备的备品备件、专用工具和仪器仪表供货表、工程概况、使用条件、技术参数要求等内容,项目单位和设计单位在招标前应结合技术发展并根据实际需求认真填写。 4. 本标准规范的投标人应答部分主要包括技术参数应答表、技术偏差表、投标产品的销售及运行业绩表、主要部件列表、推荐的备品备件、专用工具和仪器仪表供货表、培训及到货需求一览表等内容,由投标人填写。 5. 本标准规范的页面、标题等均为统一格式,不得随意更改。 6. 本规范将根据技术发展和市场变化定期或不定期做出修编,各使用单位注意查询最新版本,以免物资采购出现差错。

目录 1 总则 (1) 1.1 一般规定 (1) 1.2 投标人应提供的资质文件 (1) 1.3 工作范围和进度要求 (1) 1.4 标准和规范 (1) 1.5 需随设备提供的资料 (2) 1.6 投标时必须提供的技术数据和信息 (2) 1.7 备品备件 (2) 1.8 专用工具和仪器仪表 (2) 1.9 到货、安装、调试、验收 (2) 2 其他要求 (3) 3 试验 (3) 4 质保、技术服务 (3) 4.1 质保 (3) 4.2 技术服务 (4)

Quantum Scalar_i500安装维护手册

Quantum Scalar i500安装配置文档 二零零七年一月

目录 SCALAR I500磁带库简介 (3) 1.磁带库安装前的准备工作 (5) 2.磁带库安装步骤 (6) 3.SCALAR I500磁带库系统日志采集 (9) 4.磁带库基本维护步骤 (10) 5.SCALAR I500经常使用命令 (11)

Scalar i500磁带库简介 Scalar i500磁带库系统 A)14U库体由控制库体和扩展库体组成 B)输入输出槽位,位于磁带库前面右侧,5U控制模块有6个进出槽位,每个9U 扩展模块有12个槽位可作为进出槽位,有用于不用打开磁带库门的情况下交换磁带 C)控制面板是触摸屏,位于磁带库前面,可以通过此控制面板对磁带库的参数 进行配置和控制 D)驱动器模块,位于磁带库的背端,14U配置情况下最多可以容纳6个LTO磁 带机 E)槽位模块,用于存放磁带。位置定义见下图 F)前电源开关,用于控制库体运行上电开关 G)冷却系统出风口,用于磁带库内部部件运行在正常的温度状态下 H)扩展固定螺丝,用于两库体之间扩展固定之用

I)驱动器模块,位于磁带库的背端,14U配置情况下最多可以容纳6个LTO磁 带机 J)电源模块,标配为每一库体一路电源输入,可以升级为冗余电源支持,每一库体增加一路电源模块输入。 K)通信总线终结,用于通信总线两端的终结之用 L)库体间通信电缆,用于不同库体之间通信总线的连接之用 M)LCB,是磁带库的控制模块 注:下图为不同配置状态下,槽位的配置情况

1.磁带库安装前的准备工作 1.准备场地 请用户决定磁带库的放置位置,是直接放置在地上,还是安装在机架上。如果安装到机架上,请尽量安装到机架的底部,保证整个机架的稳定。如上机架需要购买机架套件。下表格为I500的各个部件外形尺寸和相应重量,请参考: 2.准备电源 QUANTUM Scalar i500的电源要求为220V/10A。此次14U配置需要4路电源输入,10A可串联两路电源。请用户尽早准备 3.准备管理接口 Scalar i500磁带库管理接口是一个RJ45接口,用户可以通过浏览器对磁带库进行管理。请用户为Scalar i500预留IP地址 4.管理工具用户及口令 磁带库的用户为admin,口令为password 5.光纤准备工作 为每一个磁带机准备一对光纤,机械手不用特别预留。提前在交换机上配置好ZONE

手把手教你安装IBM TS3310磁带库

手把手教你安装IBM TS3310磁带库 前不久装了回IBM的磁带库TS3310,感觉在上架方面还是有需要注意的地方,特别对于刚接触此带库的工程师来说,能有个安装手册在手就不怕在客户那里担惊受怕了。话说TS3310还真是个大家伙,特别是加上了3576-E9U这个扩展柜后更是体积暴增,一个还好对付,2、3个一上那可就费力咯。本篇文章主要针对此款磁带库的机架安装和初步的面板应用做出详细的指导,希望能对工程师们的工作有所帮助。 本文是第一篇,主要给大家介绍TS3310磁带机。 一、产品简述 TS3310 磁带机性能强大、容量大并且可靠,能够满足磁带存储的巨大要求。该磁带库模块化程度高且可伸缩性强,从基本磁带库5U控制模块,直到每个配置均是9U的附加扩展单元都在可伸缩范围内。LTO3的磁带驱动器可以读写原始LTO2数据磁带盒并读取LTO1数据磁带盒。 TS3310磁带库包含磁带库控制模块,固定盒式磁带存储器(30个插槽)、I/O站(6个插槽)、触摸显示屏、磁带盒处理自动装置以及最多两个LTO 3磁带机。 您可以将多达4个可选扩展模块添加到控制模块。每个L9U扩展模块可以容纳最多4个LTO3磁带机和最多80个盒式磁带插槽,以及12个可配置I/O站插槽。 该磁带库支持带有LVD Ultra160 SCSI或本机交换光纤通道连接的LTO3磁带机,从而能够与许多开放式系统服务器连接。 1. 前面板组件展示

1 存取口 2 电源按钮 3 绿色供电(液晶指示灯) 4 琥珀色操作员干预警报指示灯 5 操作员面板(触摸式) 6 5U控制模块 7 I/O站 8 9U扩展模块 I/O站 I/O站位于磁带库的前面板上,它将在不干扰正常磁带库操作的前提下实现磁带盒的导入和导出,一个控制模块I/O站的容量为6个磁带盒,一个9U扩展模块I/O站的容量为12个磁带盒。 注: 此磁带库会读取条形码标签以确定每个插槽中的特定磁带盒,请确保磁带库中的所有磁带盒都有适当的条形码标签。 将I/O站插槽分配给逻辑磁带库时,只有该逻辑磁带库才能访问此插槽。I/O站将由所有逻辑磁带库共享,但是I/O站插槽一次只能被一个逻辑磁带库占用。 后面板组件展示

磁带库安装使用手册V1.0

磁带库安装使用手册 二零零三年六月

版权声明 ?2003 深圳市华为技术服务有限公司 版权所有,保留一切权利。 非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本书的部分或全部,并不得以任何形式传播。 修订记录

目录 第一章磁带库设备简介 (4) 第二章磁带库的安装与调试说明 (5) 第三章标准磁带库的安装调试 (7) 3.1. 磁带库F OR S UN SOLARIS安装 (7) 3.2. 磁带库F OR HP UX安装 (8) 3.3. 磁带库F OR IBM AIX安装 (9) 第四章常见磁带库的安装调试 (11) 4.1. D ELL 128T磁带库的安装 (11) 4.2. IBM3583磁带库的安装 (11) 4.3. STK L20磁带库的安装 (13) 4.4. OVERLAND N EOSERIES磁带库的安装 (14)

第一章磁带库设备简介 随着电信、金融、保险等行业的迅速发展,需要进行备份归档的业务数据量也越来越大,简单的依靠磁带机手工备份数据已经越来越不适应这种需求的变化。人们需要一种专用的设备帮助技术人员进行工作,它可以配合各种备份管理软件完成各种数据备份、存档、磁带管理及灾难恢复等工作,支持多驱动器同时工作及自动存取磁带,极大的提高工作效率;同时它还可以支持SCSI、FC等多种接口,支持多种软硬件平台,其数据处理能力及存储容量可以根据客户需求灵活配置,这就是磁带库。磁带库正是在这种需求的驱动下应运而生的。 目前常用的磁带库一般由磁带驱动器、机械臂和磁带置放模组组成。磁带驱动器的作用是在磁带上读写数据,类似于以前使用的磁带机;机械臂的作用是用来识别和存取、移动磁带;磁带置放模组的作用是用来储存磁带的。一般磁带库中配置是一个机械臂、多个驱动器和磁带置放模组。如下图1-1为一个磁带库的示意图 图1-1 磁带库示意图

HPMSL4080磁带机安装配置

HP MSL 磁带机安装配置 二:主机准备 1:根据磁带机类型准备备份服务器需要SCSI HBA卡或者FC HBA卡2:4GB FC HBA卡需要LTO4 ;8GB HBA卡需要LTO5

三:设备安装1:移除磁带库锁 2:设备上架

3:连接FC线缆 四:配置设备 1:设备管理密码 通过OCP(操作面板)设置管理员密码(见下文)2:设置日期和时间 3: 配置网络 默认情况下设备IP有DHCP自动分发,修改为静态IP 4:配置光纤(SCSI)端口 建议采用默认配置

五:设备连接 1:安装备份软件或者驱动 2:确认主机和磁带库连接 :安装HP tapetools(诊断工具) 确定主机操作系统:settings—control panel—system—hardware—device manager—tape drive and/or media change 六:检查固件版本 MSL2024 OCP 1. From the Home screen, press Next until the display shows Status/Information. Press Enter. 2. Press Next until the display shows Library Information. Press Enter. 3. Press Next until the display shows the Firmware Rev. MSL4048, MSL8048, and MSL8096 (OCP) 1. Use the control keys to navigate to Info > Identity > Library. 2. The Library Controller FW Revision field shows the Library firmware revision.

Sun StorageTek 磁带库介绍

Oracle 磁带库产品介绍 一、全系列磁带库产品 Oracle 全系列磁带库产品包括SL24 / 48、SL500、SL3000、SL8500五款产品。产品的配置和跨度:

二、S un StorageTek SL24磁带库 需要经济实惠的高容量备份和恢复?受空间约束?Sun StorageTek SL24 自动加载磁带机为您提供可靠性、简单性以及高容量自动备份和恢复的价值,并且采用易于使用、机架就绪、空间效率高的外形尺寸。 ?非压缩自然容量可达36 TB容量(LT0 5磁带驱动器) ?可达120 MB/秒吞吐量 ?可达504 GB/小时性能 ?2U 外形尺寸 Sun StorageTek SL24磁带库产品技术规格:

?磁带驱动器: ?驱动器数: ◆LTO 4 / 5- 全高:1个 ◆LTO 4 - 半高:1个或2个 ?驱动器吞吐量: ◆LTO 4 - 半高:80 MB/秒 ◆LTO 4 - 全高:120 MB/秒 ◆LTO 5 - 全高:140 MB/秒 ?最高性能(本机): ◆LTO 4 - 全高:432 GB/小时(1个驱动器) ◆LTO 5- 全高:504 GB/小时(1个驱动器) ?磁带匣数: ?LTO 4/5 - 全高:24 ?本机容量(非压缩自然容量): ?LTO 4 - 全高:19.2 TB ?LTO 5 - 全高:36 TB 三、S un StorageTek SL48磁带库 正在寻找保护您的关键业务数据的更好方式?需要节省宝贵的机架空间?机架就绪式Sun StorageTek SL48 磁带库是备份和恢复、存档以及灾难恢复的理想选择,为您提供可靠性、简单性以及高容量自动备份和恢复的价值,并且空间

i40磁带库安装步骤

Quantum I40/I80磁带库安装及维护实施方案

一 Quantum Scalar i40 Library(FC接口)安装步骤 1.磁带库安装前的准备工作 (1)准备场地 请用户决定磁带库的放置位置,是直接放置在地上,还是安装在机架上。如果安装到机架上,请尽量安装到机架的底部,保证整个机架的稳定。 (2)准备电源 Quantum Scalar i40的电源要求为220V/10A请用户尽早准备。 (3)准备管理接口 Quantum Scalar i40磁带库管理接口是一个RJ45接口,用户可以通过浏览器对磁带库进行管理。 (4)管理工具用户及口令 磁带库的用户为admin,口令为password 2.具体安装步骤 第一步验货,拆下外包装,并将磁带库放到指定位置,上机架有特殊套件。 第二步将磁带库固定,保持水平。 第三步将位于设备顶部的用于固定机械臂装置取出,机械手可以移动。如下图所示:

第四步将磁带机装入磁带库,磁带机槽位位置如下图所示: 半高磁带机占1个槽位位置,全高磁带机需占用2 个槽位位置 第五步连接光纤到每个 磁带机上,将光纤 与光纤交换机进 行连接,或直连到 主机,将通信网线 连接安装到指定 位置。

第六步连接电缆,分别打开电源模块上开关和前面板开关。上电进行自检测试,如果没有报错说明磁带库安装正常。如果报错可以通过控制面板对磁带库进行检测。 第七步运行磁带库配置向导,特别注意需要指定磁带库IP地址和选定远程控制。须注意:时区设置无法通过操作面板进行更改,只能通过远程管理页面修改。I/E导入导出槽的设置为右侧抽屉的第一列。 第八步使用带有标签的磁带对磁带库进行检测,内容, 1.磁带入库操作,通过面板将磁带防到磁带槽位上。 2.对磁带库进行自检测试。 3.做不同位置的移动磁带的操作。 第九步将所有磁带贴上标签,然后入库。 (磁带带标图示) 第十步再次确认电缆连接和光纤连接。 第十一步到应用主机上确认主机与磁带库的连通性,确保在主机设备管理器中识别到磁带库设备。

相关主题