蒸汽焓值表
蒸汽焓值表

热焓表(饱和蒸汽或过热蒸汽)1、饱和蒸汽压力- 焓表(按压力排列)

2、饱和蒸汽温度-焓表(按温度排列)

3、过热蒸汽温度、压力-焓表(一)

4、过热蒸汽温度、压力-焓表(二)

动力蒸汽管径计算公式及焓值对照表

蒸汽部分计算书 一、蒸汽量计算:(6万平米) 市政管网过热蒸汽参数:压力=0.4MPa 温度=180℃ 密度=2.472kg/m3蒸汽焓值=2811.7KJ/kg 换热器凝结水参数:温度=70℃焓值=293 KJ/kg 密度=978kg/m3(1)采暖部分耗汽量:热负荷6160kW G=3.6*Q/Δh=3.6*6160*1000/(2811.7-293)=8805kg/h 凝结水量计算:G=m/ρ=8805/978=9m3/h (2)四十七层空调耗汽量:热负荷200kW G=3.6*Q/Δh=3.6*200*1000/(2811.7-293)=285kg/h 凝结水量计算:G=m/ρ=285/978=0.29m3/h (3)高区供暖耗汽量:热负荷1237kW G=3.6*Q/Δh=3.6*1237*1000/(2811.7-293)=1768kg/h 凝结水量计算:G=m/ρ=1768/978=1.8m3/h (4)中区供暖耗汽量:热负荷1190kW G=3.6*Q/Δh=3.6*1385*1000/(2811.7-293)=1980kg/h 凝结水量计算:G=m/ρ=1980/978=2m3/h (5)低区供暖耗汽量:热负荷1895kW G=3.6*Q/Δh=3.6*1895*1000/(2811.7-293)=2708kg/h 凝结水量计算:G=m/ρ=2708/978=2.8m3/h (6)低区空调耗汽量:热负荷1640kW G=3.6*Q/Δh=3.6*1640*1000/(2811.7-293)=2344kg/h 凝结水量计算:G=m/ρ=3830/978=4m3/h (7)生活热水耗汽量:热负荷200kW G=3.6*Q/Δh=3.6*200*1000/(2811.7-293)=286kg/h 凝结水量计算:G=m/ρ=286/978=0.3 m3/h (8)洗衣机房预留蒸汽量: 150kg/h

饱和蒸汽压力温度对照表

压力(MPa) 温度(℃) 0.001 6.9491 0.002 12.9751 0.002 17.5403 0.003 21.1012 0.003 24.1142 0.004 26.6707 0.004 28.9533 0.005 31.0533 0.005 32.8793 0.006 34.6141 0.006 36.1663 0.007 37.6271 0.007 38.9967 0.008 40.2749 0.008 41.5075 0.009 42.6488 0.009 43.7901 0.010 44.8173 0.010 45.7988 0.011 47.6934 0.012 49.4281 0.013 51.0488 0.014 52.5553 0.015 53.9705 0.016 55.3401 压力(MPa) 温度(℃) 0.017 56.5955 0.018 57.8053 0.019 58.9694 0.020 60.0650 0.021 61.1378 0.022 62.1422 0.023 63.1237 0.024 64.0596 0.025 64.9726 0.026 65.8628 0.027 66.7074 0.028 67.5291 0.029 68.3280 0.030 69.1041 0.032 70.6106 0.034 72.0144 0.036 73.3611 0.038 74.6508 0.040 75.8720 0.045 78.7366 0.050 81.3388 0.055 83.7355 0.060 85.9496 0.065 88.0154 0.070 89.9556 压力(MPa) 温度(℃) 0.075 91.7816 0.080 93.5107 0.085 95.1485 0.090 96.7121 0.095 98.2014 0.100 99.6340 0.110 102.3160 0.120 104.8100 0.130 107.1380 0.140 109.3180 0.150 111.3780 0.160 113.3260 0.170 115.1780 0.180 116.9410 0.190 118.6250 0.200 120.2400 0.210 121.7890 0.220 123.2810 0.230 124.7170 0.240 126.1030 0.250 127.4440 0.260 128.7400 0.270 129.9980 0.280 131.2180 0.290 132.4030 压力(MPa) 温度(℃) 0.300 133.5560 0.310 134.6770 0.320 135.7700 0.330 136.8360 0.340 137.8760 0.350 138.8910 0.360 139.8850 0.370 140.8550 0.380 141.8030 0.390 142.7320 0.400 143.6420 0.410 144.5350 0.420 145.4110 0.430 146.2690 0.440 147.1120 0.450 147.9330 0.460 148.7510 0.470 149.5500 0.480 150.3360 0.490 151.1080 0.500 151.8670 0.520 153.3500 0.540 154.7880 0.560 156.1850 0.580 157.5430 压力(MPa) 温度(℃) 0.600 158.8630 0.620 160.1480 0.640 161.4020 0.660 162.6250 0.680 163.8170 0.700 164.9830 0.720 166.1230 0.740 167.2370 0.760 168.3280 0.780 169.3970 0.800 170.4440 0.820 171.4710 0.840 172.4770 0.860 173.4660 0.880 174.4360 0.900 175.3890 0.920 176.3250 0.940 177.2450 0.960 178.1500 0.980 179.0400 1.000 179.9160 1.050 18 2.0480 1.100 184.1000 1.150 186.0810 1.200 187.9950 压力(MPa) 温度(℃) 1.250 189.8480 1.300 191.6440 1.350 193.3860 1.400 195.0780 1.450 196.7250 1.500 198.3270 1.550 199.8870 1.600 201.4100 1.650 20 2.8950 1.700 204.3460 1.750 205.7640 1.800 207.1510 1.850 208.5080 1.900 209.8380 1.950 211.1400 2.000 212.4170 2.050 21 3.6690 2.100 214.8980 2.150 216.1040 2.200 217.2890 2.250 218.4520 2.300 219.5960 2.350 220.7220 2.400 221.8290 2.450 222.9180 1 / 2

过热蒸汽热焓表

过热蒸汽热焓表 1、饱和蒸汽压力- 焓表(按压力排列)压力MPa 温度℃焓KJ / kg 压力MPa 温度℃焓KJ / kg 0.001 6.98 2513.8 1.00 179.88 2777.0 0.002 17.51 2533.2 1.10 184.06 2780.4 0.003 24.10 2545.2 1.20 187.96 2783.4 0.004 28.98 2554.1 1.30 191.6 2786.0 0.005 32.90 2561.2 1.40 195.04 2788.4 0.006 36.18 2567.1 1.50 198.28 2790.4 0.007 39.02 2572.2 1.60 201.37 2792.2 0.008 41.53 2576.7 1.40 204.3 2793.8 0.009 43.79 2580.8 1.50 207.1 2795.1 0.010 45.83 2584.4 1.90 209.79 2796.4 0.015 54.00 2598.9 2.00 212.37 2797.4 0.020 60.09 2609.6 2.20 217.24 2799.1 0.025 64.99 2618.1 2.40 221.78 2800.4 0.030 69.12 2625.3 2.60 226.03 2801.2 0.040 75.89 2636.8 2.80 230.04 2801.7 0.050 81.35 2645.0 3.00 233.84 2801.9 0.060 85.95 2653.6 3.50 242.54 2801.3 0.070 89.96 2660.2 4.00 250.33 2799.4 0.080 93.51 2666.0 5.00 263.92 2792.8 0.090 96.71 2671.1 6.00 275.56 2783.3 0.10 99.63 2675.7 7.00 285.8 2771.4 0.12 104.81 2683.8 8.00 294.98 2757.5 0.14 109.32 2690.8 9.00 303.31 2741.8 0.16 113.32 2696.8 10.0 310.96 2724.4 0.18 116.93 2702.1 11.0 318.04 2705.4 0.20 120.23 2706.9 12.0 324.64 2684.8 0.25 127.43 2717.2 13.0 330.81 2662.4 0.30 133.54 2725.5 14.0 336.63 2638.3 0.35

蒸汽和饱和蒸汽热焓表

热焓表(饱和蒸汽或过热蒸汽)1、饱和蒸汽压力- 焓表(按压力排列)

2601134 280 3001329 350 4003004 420 440 450 460 480 50033233165 5203237 540 550 560 580 6003624 1吨标准煤发热量29,307,600KJ, 或7000大卡, 1吨300度饱和蒸汽大约折合吨标准煤。 1吨280度的1MPa的过热蒸汽热焓为*1000kj=3,008,300kj 1吨280度的1MPa的过热蒸汽折合3008300/=吨标煤 1度电=404g标煤大型电厂折合390g标煤 1吨标煤减排二氧化碳(t-CO2/tce) 1度电折合二氧化碳:*404g= 1度(千瓦时)= 3600000焦耳,而标准煤的定义是:凡能产生的热量(低位)的任何数量的燃料折合为1kg标准煤。这样就可以算出来理论上(即能量完全转化的情况下)一千克标准煤可以发多少电了。 不过,实际上因为不可能完全转化,所以肯定会低于理论值。国家发改委提供的数据是火电厂平均每千瓦时供电煤耗由2000年的392g标准煤降到360g标准煤,2020年达到320g标准煤。即一千克标准煤可以发三千瓦时的电。 按2009年全国发电标煤消耗342克/度计算: 1、反应式:C + O2 = CO2 2、条件:标煤碳元素含量85%(重量);C分子量12;CO2分子量44; 理想气体常数升/摩尔。 则每发一度电产生的二氧化碳为:342克×12×44=克 1万立方的水如何折成吨标煤 悬赏分:50 - 解决时间:2009-8-31 18:39 问题补充:

急用!我只要水的折算方法! 提问者:mapla - 二级 最佳答案 各类能源折算标准煤的参考系数 能源名称平均低位发热量折标准煤系数 原煤20934千焦/公斤0.7143公斤标煤/公斤 洗精煤26377千焦/公斤0.9000公斤标煤/公斤 其他洗煤8374 千焦/公斤0.2850公斤标煤/公斤 焦炭28470千焦/公斤0.9714公斤标煤/公斤 原油41868千焦/公斤1.4286公斤标煤/公斤 燃料油41868千焦/公斤1.4286公斤标煤/公斤 汽油43124千焦/公斤1.4714公斤标煤/公斤 煤油43124千焦/公斤1.4714公斤标煤/公斤 柴油42705千焦/公斤1.4571公斤标煤/公斤 液化石油气47472千焦/公斤1.7143公斤标煤/公斤 炼厂干气46055千焦/ 公斤1.5714公斤标煤/公斤 天然气35588千焦/立方米12.143吨/万立方米 焦炉煤气16746千焦/立方米5.714吨/万立方米 其他煤气3.5701吨/万立方米 热力吨/百万千焦 电力3.27吨/万千瓦时 1、热力其计算方法是根据锅炉出口蒸汽和热水的温度压力在焓熵图(表)内查得每千克的热焓减去给水(或回水)热焓,乘上锅炉实际产出的蒸汽或热水数量(流量表读出)计算。如果有些企业没有配齐蒸汽或热水的流量表,如没有焓熵图(表),则可参下列方法估算: (1)报告期内锅炉的给水量减排污等损失量,作为蒸汽或热水的产量。 (2)热水在闭路循环供应的情况下,每千克热焓按20千卡计算,如在开路供应时,则每千克热焓按70千卡计算(均系考虑出口温度90℃,回水温度20℃)。 (3)饱和蒸汽,压力千克/平方厘米,温度127℃以上的热焓按620千卡,压力3-7千克/平方厘米,温度135℃-165℃的热焓按630千卡。压力8千克/平方厘米,温度170℃以上每千克蒸汽按640千卡计算。 (4)过热蒸汽,压力150千克/平方厘米,每千克热焓:200℃以下按650千卡计算,220℃-260℃按680千卡计算,280℃-320℃按700千卡,350℃-500℃按700千卡计算。按焦耳折算成焦耳。 2.热力单位“千卡”与标准煤“吨”的折算能源折算系数中“蒸汽”和“热水”的计算单位为“千卡”,但“基本情况表”中(能源消耗量中)“蒸汽”计算单位为“蒸吨”,在其它能源消耗量(折标煤)其中的“热水”计算单位为“吨”,因此需要进一步折算,才能适合“基本情况表”的填报要求,按国家标准每吨7000千卡折1千克标准煤计算: 3.电力的热值一般有两种计算方法:一种是按理论热值计算,另一种是按火力发电煤耗计算。每种方法各有各的用途。理论热值是按每度电本身的热功当量860大卡即千克标准煤计算的。按火力发电煤耗计算,每年各不相同,为便于对比,以国家统计局每万度电折千克标准煤,作为今后电力折算标准煤系数。 1 吨新鲜水= kg标煤……

蒸汽温度压力对照表

根据1MPa=1000kPa=10.2kgf/cm2(kg/cm2),通过与饱和蒸气压(单位为MPA)和蒸汽标准表的比较,可以计算出饱和蒸气压(kgf/cm2)与蒸汽温度的关系。温度如下:饱和蒸汽的温度和压力之间只有一个自变量。理想饱和蒸汽状态是指温度、压力和蒸汽密度之间存在一一对应关系。如果其中一个已知,其他两个值为常量。有此关系的蒸汽为饱和蒸汽,有饱和蒸汽压力和温度的对照表。饱和蒸汽压力与蒸汽温度标准对照表按国际单位制编制,压力单位为兆帕,温度单位为摄氏度。 扩展数据 测量饱和蒸气压有两种方法 1动态方法。测定液体在不同外压下沸点的方法,又称沸点法。这种方法只能测量接近大气压的饱和蒸气压,精度高。 2静态法。它是指直接测量液体在不同温度下的饱和蒸气压,即在恒定温度下测量饱和压力。静态方法相对简单,用途更广。通常的方法是将被测材料置于密闭容器中,使其处于

气液共存状态,然后放入恒温槽中。通过调节恒温槽的温度,可以测量不同温度下的饱和蒸气压数据。 在封闭条件下,在一定温度下,与固体或液体平衡的蒸气压称为饱和蒸气压。饱和蒸汽压力也称为蒸汽压力。同一种物质在不同的温度下有不同的蒸气压,并且随着温度的升高而增加。对于同一种物质,固体的饱和蒸气压低于液体的饱和蒸气压。 饱和蒸汽是指由于气体分子之间的热运动而处于饱和状态的蒸汽。当液体在有限的封闭空间内蒸发时,液体分子通过液体表面进入上层空间,成为蒸汽分子。因为蒸汽分子处于湍流热运动中,它们相互碰撞。蒸汽压力与饱和蒸汽温度之间存在对应关系,不同压力下存在一定的饱和温度。换言之,在一定的压力下,水完全蒸发并继续吸收热量,但直到温度开始升高,温度才上升,变成饱和蒸汽。

蒸汽温度压力对照表

蒸汽: 亦称“水蒸气”。根据压力和温度对各种蒸汽的分类为:饱和蒸汽,过热蒸汽。蒸汽主要用途有加热/加湿;还可以产生动力;作为机器驱动等。 工业革命又称产业革命,是资本主义时期由工场手工业阶段到大机器生产阶段的一个飞跃,它是生产领域里的一场变革又是社会关系方面的一次革命,是资本主义政治经济发展的必然结果。工业革命的完成对资本主义国家,对世界产生了深远的影响。英国是最早进行工业革命的国家,始于18世纪60年代。19世纪初扩展到法国、美国,随后是德国、俄国、日本。而各国工业革命主要是从英国引进机器进行的。英国在工业革命中的特殊地位,使它在一个相当长的时期里成为“世界工厂”。 蒸汽温度压力对照表: 按1MPa=1000kPa=10.2kgf/cm2(公斤/平方厘米),对照饱和蒸汽压力(MPa表示)与蒸汽温度的标准表,可以计算得到饱和蒸汽压力(kgf/cm2表示)与蒸汽温度之间的关系。 饱和蒸汽的温度与压力之间一一对应,二者之间只有一个独立变量。理想的饱和蒸汽状态,指的是温度、压力及蒸汽密度三者存在一一对应的关系,知道其中一个,其他二个值就是定数。存在这种关系的蒸汽就是饱和蒸汽,并存在饱和蒸汽压力与温度对照表。标准的饱和蒸汽压力与蒸汽温度对照表是根据国际单位制进行编制的,即压力单位为MPa,温度单位为℃。

饱和蒸汽压的测量方法可以分为两类: 1.动态法。指在不同外界压力下,测定液体的沸点,又称沸点法。这种方法只在测量常压附近的饱和蒸汽压时测量精度较好。 2.静态法。指在不同温度下,直接测量液体饱和蒸汽压,即在恒温条件下测量饱和压力。静态法测量相对简单,更具普遍性,通常的做法就是将待测物质充人密闭容器,并使其处于气液两相共存状态,然后放人恒温槽中,通过调节恒温槽温度来测量不同温度下的饱和蒸汽压数据。

饱和蒸汽温度与压力对照表

饱和蒸汽温度压力对照表 问题:饱和蒸汽温度与压力对照表 说明:

蒸汽是常用的换热介质,而温度控制是 通过一定压力下的流量调节来实现的, 希望大家建立一个基本的概念。在热交 热器或者其它需要蒸汽阀门的地方,大家在选型时经常会用到。现将饱和蒸汽的温度与压力对照表整理,供大家参考!

可以说对的,10公斤绝对大气压对应的饱和蒸汽温度就是179度,楼上的说的184度是10公斤表压(也就是压力表上指示的压力;压力表是从0开始记数的,而大气本身就有1公斤的压力,绝对大气压=表压+1),184度是11公斤绝对大气压下的饱和蒸汽对应温度。这里都强调“饱和蒸汽”,因为还有“过热蒸汽”,过热蒸汽的温度是不于压力成对应关系的。 Antoine公式: ln(P)=9.3876-3826.36/(T-45.47)【T在290~500K之间】 P:MPa T:K 我用这个公式算出来是T=452.77K 约179度. 不知道对不对?请高手指教! 《饱和蒸汽压力、温度对照表》 制硝2008-05-24 10:53:57 阅读16207 评论10 字号:大中小订阅

加热室温度差=壳层压力(真空度)相应温度-加热室料液温度 蒸汽过热度=蒸汽温度-饱和蒸汽压力相应温度 压力单位非常的多,如果要全部写出来……呵呵,我还做不到,我至今也没都认识全,不过有很多很少使用。主要还是学习国际单位和几个常用单位就可以了。 常用压力单位有: 帕斯卡N/m2(Pa)千帕(kPa) 兆帕(MPa) 巴(bar)毫巴(mbar)微巴(μbar) 标准大气压(atm) 磅力/英寸^2 lb/inch2(psi) 工程大气压(kgf/cm2) 托(Torr)=毫米汞柱(mmHg) 英寸汞柱(inchHg) 毫米水柱(mmH2O) 达因/厘米2(dyn/cm2) 换算关系: 1兆帕(MPa)=1000000帕(Pa) 1巴(bar)=1000毫巴(mbar) 1毫巴(mbar)=1000微巴(μbar)=1000达因/厘米2(dyn/cm2) 1托(Torr)=1毫米汞柱(mmHg)=133.329帕(Pa) 1工程大气压=1千克力/厘米2(kgf/cm2) 1物理大气压=1标准大气压(atm)

蒸汽压力温度焓值对照表

蒸汽表(公制SI单位) 显热量 潜热量全热量显热量潜热量全热量温度(ht)(ht)比容积温度(ht)(ht)(ht)比容积(ht) ()()()()()bar kPa ℃kj/kg kj/kg kj/kg m 3/kg bar kPa ℃kj/kg kj/kg kj/kg m 3/kg 绝对压力0.303069.1289.232336.12625.3 5.229 4.50450155.55656.32096.727530.3420.505081.33340.492305.42645.9 3.24 5.00500158.92670.920862756.90.31507591783843922786221755016208684620757276030292压力 压力0.757591.78384.392278.62663 2.217 5.50550162.08684.62075.72760.30.292表压 6.50650167.83709.72056.82766.50.2550.000100419.0422572676 1.6737.00700170.5721.42047.72769.10.240.0.1010102.66430.22250.22680.2 1.5537.50750173.02732.52039.22771.70.2270.2020105.1440.82243.42684.2 1.4148.00800175.43743.12030.927740.21503010739450422372268761312850177757533202292776202040.3030107.39450.42237.22687.6 1.3128.50850177.75753.32022.92776.20.2040.4040109.55459.72231.32691 1.2259.00900179.977632015.12778.10.1940.5050111.61468.32225.62693.9 1.1499.50950182.1772.52007.527800.1850.6060113.56476.42220.42696.8 1.08810.001000184.13781.62000.12781.70.1770.7070115.4484.12215.42699.5 1.02410.501050186.05790.119932783.30.1710801171449162210527021097111001880279882784801630.8080117.14491.62210.52702.10.97111.001100188.02798.819862784.80.1630.9090118.8498.92205.6704.50.92311.501150189.82807.11979.12786.30.1571.00100120.42505.62201.12706.70.88112.001200191.68815.17972.52787.60.1511.10110121.96512.221972709.20.84112.501250193.43822.91965.42788.80.1481.20120123.46518.72192.82711.50.80613.001300195.1830.41959.627900.14113012495246218872713307731350196628379195322791101361.30130124.9524.62188.72713.30.77313.501350196.62837.91953.22791.10.1361.40140126.28530.52184.82715.30.74314.001400198.35845.11947.12792.20.1321.50150127.62536.121812717.10.71414.501450199.92852.119412793.10.1281.60160128.89541.62177.32718.90.68915.001500201.45859193527940.1241.70170130.13547.12173.72720.80.66515.501550202.92865.71928.82794.90.119180131375523217012722406431600204388723192342795701171.80180131.37552.32170.12722.40.64316.001600204.38872.31923.42795.70.1171.90190132.54557.32166.727240.62217.001700207.178851912.12797.10.112.00200133.69562.22163.32725.50.60318.001800209.9897.21901.32798.50.1052.20220135.88571.72156.92728.60.56819.001900212.479091890.52799.50.12.40240138.01580.72150.72731.40.53620.002000214.96920.31880.22800.50.099426058922144727339050921002173593131870128014009062.60260140589.22144.72733.90.50921.002100217.35931.31870.12801.40.09062.80280141.92597.421392736.40.48322.002200219.65941.91860.128020.08683.00300143.75605.32133.42738.70.46123.002300221.85952.21850.42802.60.08323.20320145.46612.92128.127410.4424.002400224.02962.21840.92803.10.07973.40340147.26202122.92742.90.44225.002500226.12972.11831.42803.50.0768360148846271211782744904052600228159816182222803800743.60360148.84627.12117.82744.90.40526.002600228.15981.61822.22803.80.0743.80380150.446342112.92746.90.38927.00 2700 230.14 990.7 1813.3 2804 0.0714 4.00 400 151.96 640.7 2108.1 2748.8 0.374 力聚

蒸汽温度压力对照表

饱和蒸汽: 未经过热处理的蒸汽称为饱和蒸汽,饱和蒸汽是在一个大气压下,温度为100度的蒸汽,温度不能再升高,是饱和状态下的蒸汽。饱和蒸汽由气体分子之间的热运动现象造成的。 原理: 当液体在有限的密闭空间中蒸发时,液体分子通过液面进入上面空间,成为蒸汽分子。由于蒸汽分子处于紊乱的热运动之中,它们相互碰撞,并和容器壁以及液面发生碰撞,在和液面碰撞时,有的分子则被液体分子所吸引,而重新返回液体中成为液体分子。开始蒸发时,进入空间的分子数目多于返回液体中分子的数目,随着蒸发的继续进行,空间蒸汽分子的密度不断增大,因而返回液体中的分子数目也增多。当单位时间内进入空间的分子数目与返回液体中的分子数目相等时,则蒸发与凝结处于动平衡状态,这时虽然蒸发和凝结仍在进行,但空间中蒸汽分子的密度不再增大,此时的状态称为饱和状态。在饱和状态下的液体称为饱和液体,其对应的蒸汽是饱和蒸汽,但最初只是湿饱和蒸汽,待蒸汽中的液态水完全蒸发后才是干饱和蒸汽。蒸汽从不饱和到湿饱和再到干饱和的过程温度是不增加的,干饱和之后继续加热则温度会上升,成为过热蒸汽。 特点: 饱和蒸汽具有如下特点: (1)饱和蒸汽的温度与压力之间一一对应,二者之间只有一个独立变量。理想的饱和蒸汽状态,指的是温度、压力及蒸汽密度三者

存在一一对应的关系,知道其中一个,其他二个值就是定数。存在这种关系的蒸汽就是饱和蒸汽,否则都可以视为过热蒸汽进行计量,如图为饱和蒸汽压力与温度对照表; (2)饱和蒸汽容易凝结,在传输过程中如有热量损失,蒸汽中便有液滴或液雾形成,并导致温度与压力的降低。含有液滴或液雾的蒸汽称为湿蒸汽。严格来说,饱和蒸汽或多或少都含有液滴或液雾的双相流体,所以,不同状态下不能用同一气体状态方程式来描述。饱和蒸汽中液滴或液雾的含量反映了蒸汽的质量,一般用干度这一参数来表示。蒸汽的干度是指单位体积饱和蒸汽中干蒸汽所占的百分数,以“x”表示; (3)准确计量饱和蒸汽流量比较困难,因为饱和蒸汽的干度难以保证,一般流量计都不能准确检测双相流体的流量,蒸汽压力波动将引起蒸汽密度的变化,流量计示值产生附加误差。所以在蒸汽计量中,必须设法保持测量点处蒸汽的干度以满足要求,必要时还应采取补偿措施,实现准确的测量。

饱和蒸汽焓值表

(单位:密度ρ为kg/m3,压力P为MPa,温度t为℃) 温度t 0 1 2 3 4 ℃ 压力P 密度ρ压力P 密度ρ压力P 密度ρ压力P 密度ρ压力P 密度ρ 100 0.1013 0.5977 0.1050 0.6180 0.1088 0.6388 0.1127 0.6601 0.1167 0.6952 110 0.1433 0.8265 0.1481 0.8528 0.1532 0.8198 0.1583 0.9075 0.1636 0.9359 120 0.1985 1.122 0.2049 1.155 0.2114 1.190 0.2182 1.225 0.2250 1.261 130 0.2701 1.497 0.2783 1.539 0.2867 1.583 0.2953 1.627 0.3041 1.672 140 0.3614 1.967 0.3718 2.019 0.3823 2.073 0.3931 2.129 0.4042 2.185 150 0.4760 2.548 0.4888 2.613 0.5021 2.679 0.5155 2.747 0.5292 2.816 160 0.6181 3.260 0.6339 3.339 0.6502 3.420 0.6666 3.502 0.6835 3.586 170 0.7920 4.123 0.8114 4.218 0.8310 4.316 0.8511 4.415 0.8716 4.515 180 1.0027 5.160 1.0259 5.274 1.0496 5.391 1.0737 5.509 1.0983 5.629 190 1.2551 6.397 1.2829 6.532 1.3111 6.671 1.3397 6.812 1.3690 6.955 200 1.5548 7.864 1.5876 8.025 1.6210 8.188 1.6548 8.354 1.6892 8.522 210 1.9077 9.593 1.9462 9.782 1.9852 9.974 2.0248 10.17 2.0650 10.37 220 2.3198 11.62 2.3645 11.84 2.4098 12.07 2.4559 12.30 2.5026 12.53 230 2.7975 14.00 2.8491 14.25 2.9010 14.52 2.9546 14.78 3.0085 15.05 240 3.3477 16.76 3.4070 17.06 3.4670 17.37 3.5279 17.68 3.5897 17.99 温度t 5 6 7 8 9 ℃ 压力P 密度ρ压力P 密度ρ压力P 密度ρ压力P 密度ρ压力 P 密度ρ 100 0.1208 0.7105 0.1250 0.7277 0.1294 0.7515 0.1339 0.7758 0.1385 0.8008

蒸汽温度与焓值对照表

热焓表(饱和蒸汽或过热蒸汽) 1)饱和蒸汽压力- 焓表(按压力排列) 压力MPa 温度℃焓KJ / kg 压力MPa 温度℃焓KJ / kg 0.001 6.98 2513.8 1.00 179.88 2777.0 0.002 17.51 2533.2 1.10 184.06 2780.4 0.003 24.10 2545.2 1.20 187.96 2783.4 0.004 28.98 2554.1 1.30 191.6 2786.0 0.005 32.90 2561.2 1.40 195.04 2788.4 0.006 36.18 2567.1 1.50 198.28 2790.4 0.007 39.02 2572.2 1.60 201.37 2792.2 0.008 41.53 2576.7 1.40 204.3 2793.8 0.009 43.79 2580.8 1.50 207.1 2795.1 0.010 45.83 2584.4 1.90 209.79 2796.4 0.015 54.00 2598.9 2.00 212.37 2797.4 0.020 60.09 2609.6 2.20 217.24 2799.1 0.025 64.99 2618.1 2.40 221.78 2800.4 0.030 69.12 2625.3 2.60 226.03 2801.2 0.040 75.89 2636.8 2.80 230.04 2801.7 0.050 81.35 2645.0 3.00 233.84 2801.9 0.060 85.95 2653.6 3.50 242.54 2801.3 0.070 89.96 2660.2 4.00 250.33 2799.4 0.080 93.51 2666.0 5.00 263.92 2792.8 0.090 96.71 2671.1 6.00 275.56 2783.3 0.10 99.63 2675.7 7.00 285.8 2771.4 0.12 104.81 2683.8 8.00 294.98 2757.5 0.14 109.32 2690.8 9.00 303.31 2741.8 0.16 113.32 2696.8 10.0 310.96 2724.4 0.18 116.93 2702.1 11.0 318.04 2705.4 0.20 120.23 2706.9 12.0 324.64 2684.8 0.25 127.43 2717.2 13.0 330.81 2662.4 0.30 133.54 2725.5 14.0 336.63 2638.3 0.35 138.88 2732.5 15.0 342.12 2611.6 0.40 143.62 2738.5 16.0 347.32 2582.7 0.45 147.92 2743.8 17.0 352.26 2550.8 0.50 151.85 2748.5 18.0 356.96 2514.4 0.60 158.84 2756.4 19.0 361.44 2470.1 0.70 164.96 2762.9 20.0 365.71 2413.9 0.80 170.42 2768.4 21.0 369.79 2340.2 0.90 175.36 2773.0 22.0 373.68 2192.5

饱和水蒸气焓值表

压力 温度 汽化潜热 p tγ Mpa℃m3/kg m3/kg kJ/kg kJ/kg kJ/kg kJ/(kg·K)kJ/(kg·K)0.001 6.94910.0010001129.18529.212513.292484.10.10568.9735 0.00217.54030.001001467.00873.582532.712459.10.26118.722 0.00324.11420.001002845.666101.072544.682443.60.35468.5758 0.00428.95330.001004134.796121.32553.452432.20.42218.4725 0.00532.87930.001005328.101137.722560.552422.80.47618.393 0.00636.16630.001006523.738151.472566.4824150.52088.3283 0.00738.99670.001007520.528163.312571.562408.30.55898.2737 0.00841.50750,0010085 18.102173.812576.062402.30.59248.2266 0.00943.79010.001009416.204183.362580.152396.80.62268.1854 0.0145.79880.001010314.673191.762583.7223920.6498.1481 0.01553.97050.00101410.022225.932598.212372.30.75488.0065 0.0260.0650.00101727.6497251.432608.92357.50.8327.9068 0.02564.97260.0010198 6.2047271.962617.432345.50.89327.8298 0.0369.10410.0010222 5.2296289.262624.562335.30.9447.7671 0.0475.8720.0010264 3.9939317.612636.12318.5 1.0267.6688 0.0581.33880.0010299 3.2409340.552645.312304.8 1.09127.5928 0.0685.94960.0010331 2.7324359.912652.972293.1 1.14547.531 0.0789.95560.0010359 2.3654376.752659.552282.8 1.19217.4789 p tγ Mpa℃m3/kg m3/kg kJ/kg kJ/kg kJ/kg kJ/(kg·K)kJ/(kg·K)0.0893.51070.0010385 2.0876391.712665.332273.6 1.2337.4339 0.0996.71210.0010409 1.8698405.22670.482265.3 1.26967.3943 0.199.6340.0010432 1.6943417.522675.142257.6 1.30287.3589 0.12104.810.0010473 1.4287439.372683-26 2243.9 1.36097.2978 0.14109.3180.001051 1.2368458.442690.222231.8 1.4117.2462 0.16113.3260.0010544 1.09159475.422696.292220.9 1.45527.2016 0.18116.9410.00105760.97767490.762701.692210.9 1.49467.1623 0.2120.240.00106050.88585504.782706.532201.7 1.53037.1272 0.25127.4440.00106720.71879535.472716-83 2181.4 1.60757.0528 0.3133.5560.00107320.60587561.582725.262163.7 1.6721 6.9921 0.35138.8910.00107860.52427584.452732.372147.9 1.7278 6.9407 0.4143.6420.00108350.46246604.872738.492133.6 1.7769 6.8961 0.5151.8670.00109250.37486640.352748.592108.2 1.861 6.8214 0.6158.8630.00110060.31563670.672756.662086 1.9315 6.76 0.7164.9830.00110790.27281697.322763.292066 1.9925 6.7079 0.8170.4440.00111480.24037721.22768.862047.7 2.0464 6.6625 0.9175.3890.00112120.21491742.92773.592030.7 2.0948 6.6222 1179.9160.00112720.19438762.842777.672014.8 2.1388 6.5859饱和水和饱和水蒸气热力性质表(按压力排列) 比熵 比焓 比体积

蒸汽温度压力对照表

蒸汽温度压力对照表 压水堆核电站哪些地方存在饱和状态呢? (1)一回路冷却剂系统稳压器中为大容积池式沸腾饱和状态; (2)压水对堆芯最热通道允许出现过冷沸腾,通道出口处允许出现低含汽量饱和泡核沸腾; (3)蒸汽发生器、除氧器、二回路混合式低加、凝汽器等加热器和冷凝器。 众所周知,饱和温度和饱和压力一一对应,我们经常用到水的饱和温度压力对照表,此表中列举的都是整数参数,使用过程中请自行插值计算,或者哪位兄台帮我开发一个微信小程序(可以自动进行插值计算)方便大家使用也未可知。 搬砖客在此先行谢过! 压水堆核电机组使用的饱和水和饱和蒸汽表,供学习使用,需注意此表主要用于日常学习,若工作或工程计算需要使用,请查询专业图标或软件。 一定温度下的液体置于密闭容器中,当单位时间由液体变为蒸气

的分子数目与由蒸气变为液体的分子数目相等时,气液两相处于动平衡状态,此时饱和蒸气所呈现的压力称为蒸气压。 蒸气压的大小与液体的种类、温度的高低有关。 当空气中所含水蒸气的量达到最大时就称这种空气为“饱和湿空气”,与饱和湿空气对应的压力称为饱和水蒸气压力。 饱和水蒸气压力表 蒸汽需要减压的原因相当简单。每一个用汽设备都有其最大允许工作压力(MAWP)。如果该压力比蒸汽供应压力低,那么就需要一个减压阀将供汽压力降低到MAWP。在减压阀可能失效的情况下,系统中还必须安装安全阀。 大多数蒸汽锅炉的设计压力都相对较高,且不应运行在较低的压力下,那样会导致蒸汽干度下降。由于这个原因,通常比较经济的做法是高压输送蒸汽,然后在使用点进行减压。这样布置还有另外一个优点,即可以减少蒸汽主管的口径,因为在高压下,蒸汽的比容较小。由于饱和蒸汽的温度和压力是一一对应的,压力控制比较简单且可以提供精确的温度控制。这一点在杀菌锅和接触式干燥器上比较普遍,因为这些设备的表面温度很难通过温度感应器测量。