Test Equipment Solutions Datasheet Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of quality test & measurement (T&M) equipment. We stock all major equipment types such as spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.
We are focused at the professional end of the marketplace, primarily working with customers for whom high performance, quality and service are key, whilst realising the cost savings that second user equipment offers. As such, we fully test & refurbish equipment in our in-house, traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2 year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of combined experience,which enables us to deliver industry-leading service and support. We endeavour to be customer focused in every way right down to the detail, such as offering free delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan unit, if available) and supplying a free business tool with every order.
As well as the headline benefit of cost saving, second user offers shorter lead times, higher reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and offers fast delivery, ?exibility, try-before-you-buy, zero capital expenditure, lower risk and off balance sheet accounting. Both second user and rental improve the key business measure of Return On Capital Employed.
We are based near Heathrow Airport in the UK from where we supply test equipment worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house Lab.
All products supplied by Test Equipment Solutions include:
- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.
Test equipment Solutions Ltd
Unit 8 Elder Way
Waterside Drive
Langley
Berkshire
SL3 6EP
T: +44 (0)1753 596000
F: +44 (0)1753 596001
Email: info@https://www.sodocs.net/doc/3016414804.html,
Web: https://www.sodocs.net/doc/3016414804.html,
Agilent N5700 Series
System DC Power Supplies
Models: N5741A-49A, N5750A-52A, N5761A-69A, N5770A-72A
Data Sheet
? 24 models: 750 W and 1500 W output power ? Up to 600 V and up to 180 A ? Small high density 1 U package
? Built-in voltage and current measurement ? Full protection from over-voltage and over-current ? 85-265 Vac universal AC input
? Command compatibility for Sorensen DLM and Xantrex XFR DC supplies ? LAN, USB, and GPIB interfaces standard ? Fully compliant to LXI Class C specification
?
Family of Affordable Basic System DC Power Supplies
The Agilent N5700 Series system DC power supplies give you just the right performance — at just the right price — in a compact (1 U) package. This family of affordable 750 W and 1500 W single-output programmable DC power supplies consists of 24 models for simple DC power applications. They provide stable output power, built-in voltage and current measurement, and out-put voltage and current from 6 V to 600 V and 1.3 A to 180 A.
These economical supplies offer many system-ready features like multiple standard I/O interfaces to simplify and accelerate test-system development for R&D, design valida-tion, and manufacturing engineers in the aerospace/defense, automotive, component and communications industries.
Small, high-density package saves you rack space
The N5700 provides up to 1500 W in a small space-saving 1 U-high, 19-inch-wide package. Its air vents are in the front, side and rear (not on the top or bottom), so you can stack other instruments directly above or below it to save valuable rack space.
2
Figure 1. Front-panel control knobs and buttons make it easy to use N5700 power supplies.
Figure 2. Built-in Ethernet, USB 2.0, and GPIB interfaces enable easy system connections.
Easy front-panel operation
You can quickly and easily operate the power supply with its rotary knobs and buttons. Using the front-panel controls, you can make coarse or fine adjustments of output voltage and current, protection settings, and set power-on states (last setting memory or factory default setting). The output voltage and current are displayed simultaneously, and LED indicators show power supply status and operating modes. You can lock the front panel controls to protect against accidental power-supply parameter changes.
Extensive device protection
To safeguard your device from damage, the N5700 Series power supplies provide over-temperature, over-current and over-voltage protec-tion (OVP) to shut down the power supply output when a fault condition occurs. They also offer an under-voltage limit (UVL) that prevents adjustment of the output voltage below a certain limit. The combina-tion of UVL and OVP capabilities lets you create a protection window for sensitive load circuitry.
Simplify system connections
The N5700 Series power supplies come standard with GPIB, Ethernet/LAN, and USB 2.0 interfaces giving you the flexibility to use your I/O interface of choice today and in the future. The N5700 is fully compliant with the LXI Class C specification.
Remote access and control The built-in Web server provides remote access and control of the instrument via a standard browser such as Microsoft? Internet Explorer. Using the Web browser, you can set up, monitor and operate the N5700 remotely.
Easy system integration and configuration
To simplify system development, the N5700 comes standard with IVI-COM drivers. The N5700 supports the easy-
to-use SCPI (Standard Commands for Programmable Instruments). Command compatibility
The N5700 includes a compatibility command set for the Xantrex XFR series power supplies, the Sorensen DLM series power supplies, and the Agilent 603x series power supplies. This simplifies system integration when converting to the N5700. For a comparison of these products, see application notes:
? S ide-by-side comparison:
Agilent N5700 Series System DC Source and Sorensen DLM DC Power Supply, AN 1502-1,
5989-1628EN
? S ide-by-side comparison: Agilent N5700 Series System DC Source and Xantrex XFR
AN 1502-2, 5989-1630EN Flexible configuration:
connect multiple units in
parallel and series
Should you need greater output power,
the N5700 series power supplies give
you the flexibility to connect in paral-
lel up to four similarly rated units for
greater output current and connect
two similarly rated units in series for
greater output voltage (see output
terminal isolation information).
Analog programming and
monitoring
The output voltage and current can
be programmed from zero to full scale
by either an analog voltage 0 to 5 V
or 0 to 10 V or by resistances of
0 to 5 k? or 0 to 10 k?.
Universal AC input
All N5700 models have universal AC
input so they can be automatically
operated from any AC mains input
voltage worldwide. They can be
operated from line voltages of
85 – 265 Vac, 47 to 63 Hz, with no
switch to set or fuses to change
when you switch from one voltage
standard to another. They also
provide power factor correction.
Rack mounting
The rack mount ears and handles
are provided standard with every unit.
In addition the N5740A rack mount
slide kit makes it easy to integrate an
N5700 into a test rack by providing
all the necessary hardware to rack
mount an N5700 series power supply
in only 1 U of rack space.
Figure 3. N5700 series web graphical user interface for remote access and control of the
power supply.
3
Performance specifications
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.
Current 25 mA23 mA17 mA12.6 mA
(change from 85-132 VAC input Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV Current 12 mA11 mA8 mA 5.8 mA
Voltage 0.05%+ 3 mV 4 mV 6.25 mV10 mV Current 0.1%+100 mA90 mA60 mA38 mA Voltage0.1%+ 6 mV8 mV12.5 mV20 mV Current0.1%+300 mA270 mA180 mA114 mA
Load transient recovery time4Time≤1.5 ms≤1.5 ms≤1.5 ms≤1 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical
performance determined either by design or type testing
(settle to within ±1.0% of the rated output, with a resistive Up, full load0.08 s0.08 s0.08 s0.08 s Down, full load0.05 s0.05 s0.05 s0.05 s Down, no load0.5 s0.6 s0.7 s0.8 s
55 ms
Remote sense compensation Volts/load lead 1 V 1 V 1 V 1 V
Range 0.5–7.5 V0.5–10 V1–15 V1–24 V
Accuracy 0.06 V0.08 V0.125 V0.20 V
CC rms 200 mA180 mA120 mA76 mA
Voltage0.72 mV0.96 mV 1.5 mV 2.4 mV
Current 12 mA10.8 mA7.2 mA 4.56 mA
Voltage 0.03 V0.04 V0.06 V0.10 V
Current 0.50 A0.45 A0.30 A0.19 A
Notes:
1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.
Minimum current is guaranteed to a maximum of 0.4% of the rated output current.
2 Up to 20 MHz
3 From 5 Hz – 1 MHz
4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.
Voltage set point from 10% to 100% of rated output
5 Add this to the output reponse time to obtain the total programming time
6 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)
4
Performance specifications
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.
Current 7.5 mA 6.9 mA 6.5 mA 6 mA
(change from 85-132 VAC input Voltage8 mV10 mV12 mV17 mV Current 3.25 mA 2.95 mA 2.75 mA 2.5 mA
Voltage 0.05%+30 mV40 mV50 mV75 mV Current 0.1%+12.5 mA9.5 mA7.5 mA 5 mA Voltage0.1%+60 mV80 mV100 mV150 mV Current0.1%+37.5 mA28.5 mA22.5 mA15 mA
Load transient recovery time4Time≤1 ms≤1 ms≤1 ms≤2 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical
performance determined either by design or type testing
(settle to within ±1.0% of the rated output, with a resistive Up, full load0.08 s0.15 s0.15 s0.15 s Down, full load0.08 s0.15 s0.15 s0.15 s Down, no load 1.1 s 1.2 s 1.5 s 2.0 s
55 ms
Remote sense compensation Volts/load lead 3 V 4 V 5 V 5 V
Range 5–66 V5–88 V5–110 V5–165 V
Accuracy 0.60 V0.80 V 1 V 1.5 V
CC rms 38 mA29 mA23 mA18 mA
Voltage7.2 mV9.6 mV12 mV18 mV
Current 1.5 mA 1.14 mA0.9 mA0.6 mA
Voltage 0.3 V0.4 V0.5 V0.75 V
Current 0.0625 A0.0475 A0.0375 A0.0250 A
Notes:
1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.
Minimum current is guaranteed to a maximum of 0.4% of the rated output current.
2 Up to 20 MHz
3 From 5 Hz – 1 MHz
4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.
Voltage set point from 10% to 100% of rated output
5 Add this to the output reponse time to obtain the total programming time
6 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)
5
Performance specifications
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.
Current41 mA38 mA29 mA20.2 mA
(change from 85-132 VAC input Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV Current20 mA18.5 mA14 mA9.6 mA
Voltage 0.05%+ 3 mV 4 mV 6.25 mV10 mV Current0.1%+180 mA165 mA120 mA76 mA Voltage0.1%+ 6 mV8 mV12.5 mV20 mV Current0.1%+540 mA495 mA360 mA228 mA
Load transient recovery time4Time≤1.5 ms≤1.5 ms≤1.5 ms≤1 ms Supplemental characteristics Supplemental characteristics are not warranted but are descriptions of typical
performance determined either by design or type testing.
(settle to within ±1.0% of the rated output, with a resistive Up, full load0.08 s0.08 s0.08 s0.08 s Down, full load0.05 s0.05 s0.05 s0.05 s Down, no load0.5 s0.6 s0.7 s0.8 s
55 ms
Remote sense compensation Volts/load lead 1 V 1 V 1 V 1 V
Range 0.5–7.5 V0.5–10 V1–15 V1–24 V
Accuracy0.06 V0.08 V0.125 V0.20 V
CC rms 360 mA330 mA240 mA152 mA
Voltage0.72 mV0.96 mV 1.5 mV 2.4 mV
Current 21.6 mA19.8 mA14.4 mA9.12 mA
Voltage 0.03 V0.04 V0.0625 V0.1 V
Current 0.90 A0.825 A0.60 A0.38 A
Notes:
1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.
Minimum current is guaranteed to a maximum of 0.4% of the rated output current.
2 Up to 20 MHz
3 From 5 Hz – 1 MHz
4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.
Voltage set point from 10% to 100% of rated output
5 Add this to the output reponse time to obtain the total programming time
6 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)
6
Performance specifications
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.
Current 10 mA8.8 mA8 mA7 mA
(change from 85-132 VAC input Voltage8 mV10 mV12 mV17 mV Current 4.5 mA 3.9 mA 3.5 mA 3 mA
Voltage 0.05%+30 mV40 mV50 mV75 mV Current 0.1%+25 mA19 mA15 mA10 mA Voltage0.1%+60 mV80 mV100 mV150 mV Current0.1%+75 mA57 mA45 mA30 mA
Load transient recovery time4Time≤1 ms≤1 ms≤1 ms≤2 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical
performance determined either by design or type testing
(settle to within ±1.0% of the rated output, with a resistive Up, full load0.08 s0.15 s0.15 s0.15 s Down, full load0.08 s0.15 s0.15 s0.15 s Down, no load 1.1 s 1.2 s 1.5 s 2.0 s
55 ms
Remote sense compensation Volts/load lead 3 V 4 V 5 V 5 V
Range 5–66 V5–88 V5–110 V5–165 V
Accuracy 0.60 V0.80 V 1 V 1.5 V
CC rms 75 mA57 mA45 mA35 mA
Voltage7.2 mV9.6 mV12 mV18 mV
Current 3 mA 2.28 mA 1.8 mA 1.2 mA
Voltage 0.3 V0.4 V0.5 V0.75 V
Current 0.125 A0.095 A0.075 A0.050 A
Notes:
1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.
Minimum current is guaranteed to a maximum of 0.4% of the rated output current.
2 Up to 20 MHz
3 From 5 Hz – 1 MHz
4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.
Voltage set point from 10% to 100% of rated output
5 Add this to the output reponse time to obtain the total programming time
6 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)
7
Series and parallel capability Parallel operation
Up to 4 units can be connected in master/slave mode
Series operation
Up to 2 units can be connected in series
Output terminal isolation
6 V to 60 V units
No output terminal may be more than ±60 VDC from any other terminal or chassis ground
80 V to 600 V units
No output terminal may be more than ±600 VDC from any other terminal or chassis ground
Store-recall states
Volatile memory locations: 16 Analog programming
(of output voltage and current)
Input signal
Selectable;
0 to 5 V / 0 to 10 V full scale
Input impedance
Selectable;
0 to 5 k? / 0 to 10 k? full scale Interface capabilities
GPIB
SCPI – 1993, IEEE 488.2 compliant interface
USB 2.0
Requires Agilent I/O library version L.01.01
10/100 LAN
Requires Agilent I/O library version L.01.01Web server
Built-in Web server requires Internet
Explorer 5+ or Netscape 6.2+
Environmental conditions
Environment
Indoor use, installation category II
(AC input), pollution degree 2
Operating temperature
0°C to 40°C @ 100% load
Storage temperature
–20°C to 70°C
Operating humidity
30% to 90% relative humidity
(no condensation)
Storage humidity
10% to 95% relative humidity
(no condensation)
Altitude
? Up to 3000 meters.
Derate the output current by
2%/100 m above 2000 m.
? Derate the maximum ambient
temperature by 1°C/100 m above
2000 m.
Regulatory compliance
EMC
? European EMC directive 89/336/
EEC for Class A products
? Australian C- Tick mark
? This ISM device complies with
Canadian ICES-001.
? Cet appareil ISM est conforme à la
norme NMB-001 du Canada.
Safety
? European Low Voltage Directive
73/23/EEC
? US and Canadian safety standards
? Any LEDs used in this product are
Class 1 as per IEC 825-1
Acoustic noise declaration
Emission directive:
? Sound pressure Lp <70 dB(A),
At operator position,
*Normal operation,
*According to EN 27779 (Type
Test).
? Schalldruckpegel Lp <70 dB(A)
*Am Arbeitsplatz, *Normaler
Betrieb, *Nach EN 27779
(Typprüfung).
AC input
Nominal input
100 – 240 VAC; 50/60 Hz
Input current 750 W
10.5 A @ 100 VAC nominal;
5 A @ 200 VAC nominal
Input current 1500 W
21 A @ 100 VAC nominal;
11 A @ 200 VAC nominal
Input range
85 – 265 VAC; 47 – 63 Hz.
Power factor
0.99 at nominal input and rated
output power
Efficiency
76% – 87% for 750 W units;
77% – 88% for 1500 W units
Inrush current
<25 A for 750 W units;
<50 A for 1500 W units
Dimensions
(excluding connectors, and handles)
Height 43.6 mm (1.72 in)
Width 422.8 mm (16.65 in)
Depth 432.8 mm (17.04 in)
Weight
750 W 7 Kg (15.4 lbs.)
1500 W 8.5 Kg (18.7 lbs.)
WARNING Shock Hazard
? F or models up to 60 VDC rated output, no point on the output shall be more than ± 60 VDC above or below chassis ground.? F or models greater than 60 VDC rated output, no point on the Positive output shall be more than ± 600 VDC above or below chassis ground.
? F or models greater than 60 VDC rated output, no point on the Negative output shall be more than ± 400 VDC above or below chassis ground.
Supplemental Characteristics for All Model Numbers
8
9
GPIB
ANALOG PROGRAMMING NOT ACTIVE AC INPUT
J1
TX
LINK
10/100 Ethernet
422.8 mm
+V –V
507.0 mm
433.0 mm
92.0 mm 92.0 mm
21.0 mm
A A
Outline Diagram
AC input
Strain-relief detail 1500 W models
39.5 mm
22.0 mm
3.0 mm
35.0 mm
Front and Rear Panel Detail
Front Panel
(All Models)
= air flow (in front, out rear) Rear Panel*
(6 V to 60 V, 1500 W Models)
(80 V to 600 V, 1500 W Models)
(6 V to 60 V, 750 W Models)
(80 V to 600 V, 750 W Models)
10
Ordering Information
Available models
System DC Power Supply 150 V, 5 A, 750 W
System DC Power Supply 300 V, 2.5 A, 750 W
System DC Power Supply600 V, 1.3 A, 780 W
System DC Power Supply 6 V, 180 A, 1080 W
System DC Power Supply 8 V, 165 A, 1320 W
System DC Power Supply 12.5 V, 120 A, 1500 W
System DC Power Supply 20 V, 76 A, 1520 W
System DC Power Supply 30 V, 50 A, 1500 W
System DC Power Supply 40 V, 38 A, 1520 W
System DC Power Supply 60 V, 25 A, 1500 W
System DC Power Supply 80 V, 19 A, 1520 W
System DC Power Supply 100 V, 15 A, 1500 W
System DC Power Supply 150 V, 10 A, 1500 W
System DC Power Supply 300 V, 5 A, 1500 W Options
750 W Models
Opt 900 Power Cord, United Kingdom Opt 902 Power Cord, Europe
Opt 903 Power Cord, USA, Canada Opt 918 Power Cord, Japan
Opt 922 Power Cord, China
1500 W Models
Opt 861 Unterminated Power Cord,
USA, Canada, Japan, China,
Other
Opt 862 Harmonized Unterminated
Power Cord, Europe Accessories
N5740A Rack Mount Slide Kit
(required for rack mounting;
standard system 11 rack-
mounting hardware will not
work)
Related Literature
These application notes will help you compare Agilent system DC sources with power supplies from other manufacturers:
? Side-by-Side Comparison: Agilent N5700 Series System DC Source and Sorensen DLM DC Power Supply, AN 1502-1, 5989-1628EN
https://www.sodocs.net/doc/3016414804.html,/
litweb/pdf/5989-1628EN.pdf
? How to Convert from a Sorensen DLM to an Agilent N5700,
AN 1503-1, 5989-1629EN
https://www.sodocs.net/doc/3016414804.html,/
litweb/pdf/5989-1629EN.pdf ? S ide-by-S ide Comparison:
Agilent N5700 Series System DC
Source and Xantrex XFR System
Power Supplies, AN 1502-2,
5989-1630EN
https://www.sodocs.net/doc/3016414804.html,/
litweb/pdf/5989-1630EN.pdf
? How to Convert from a Xantrex
XFR to an Agilent N5700,
AN 1503-2, 5989-1631EN
https://www.sodocs.net/doc/3016414804.html,/
litweb/pdf/5989-1631EN.pdf
? Trends in Medium Power (~1 kW)
DC Power Supplies, 5989-1331EN
https://www.sodocs.net/doc/3016414804.html,/
litweb/pdf/5989-1331EN.pdf
Agilent’s IO Libraries Suite ships
with the N5700 to help you quickly
establish an error-free connection
between your PC and instruments -
regardless of the vendor. It provides
robust instrument control and works
with the software development
environment you choose.
For additional description of Agilent’s
IO Libraries Suite features and instal-
lation requirements, please go to
https://www.sodocs.net/doc/3016414804.html,/find/iosuite-
datasheet
11
Agilent Email Updates
https://www.sodocs.net/doc/3016414804.html,/find/emailupdates Get the latest information on the products and applications you select. https://www.sodocs.net/doc/3016414804.html,
LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent
is a founding member of the LXI consortium.
Agilent Channel Partners
w w https://www.sodocs.net/doc/3016414804.html,/find/channelpartners Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience.For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: https://www.sodocs.net/doc/3016414804.html,/find/contactus Americas
Canada (877) 894 4414 Brazil (11) 4197 3500 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 375 8100
Europe & Middle East
Belgium
Denmark 45 70 13 15 15
Finland 358 (0) 10 855 2100
France 0825 010 700*
*0.125
€/minute
Germany 49 (0) 7031 464 6333
Ireland 1890 924 204
Israel 972-3-9288-504/544
Italy 39 02 92 60 8484
Netherlands 31 (0) 20 547 2111
Spain 34 (91) 631 3300
Sweden 0200-88 22 55
United Kingdom 44 (0) 131 452 0200
For other unlisted countries:
https://www.sodocs.net/doc/3016414804.html,/find/contactus
Revised: June 8, 2011
Product specifications and descriptions
in this document subject to change
without notice.
? Agilent Technologies, Inc. 2011
Published in USA, August 22, 2011
5989-1330EN
https://www.sodocs.net/doc/3016414804.html,
https://www.sodocs.net/doc/3016414804.html,/find/
dcpowersupplies
Agilent Advantage Services is committed
to your success throughout your equip-
ment’s lifetime. To keep you competitive,
we continually invest in tools and
processes that speed up calibration and
repair and reduce your cost of ownership.
You can also use Infoline Web Services
to manage equipment and services more
effectively. By sharing our measurement
and service expertise, we help you create
the products that change our world.
https://www.sodocs.net/doc/3016414804.html,/quality
https://www.sodocs.net/doc/3016414804.html,/find/advantageservices
https://www.sodocs.net/doc/3016414804.html,
AdvancedTCA? Extensions for
Instrumentation and Test (AXIe) is
an open standard that extends the
AdvancedTCA for general purpose
and semiconductor test. Agilent
is a founding member of the AXIe
consortium.
https://www.sodocs.net/doc/3016414804.html,
PCI eXtensions for Instrumentation
(PXI) modular instrumentation
delivers a rugged, PC-based high-
performance measurement and
automation system.
Microsoft and Windows are U.S. registered
trademarks of Microsoft Corporation
For the latest and complete specifica-
tions, refer to the N5700 User’s Guide,
Agilent part number 5969-2917. The
web contains the most up-to-date
version of the User’s Guide. Go to
https://www.sodocs.net/doc/3016414804.html,/find/N5700