搜档网
当前位置:搜档网 › Agilent-N5770A-Datasheet

Agilent-N5770A-Datasheet

Test Equipment Solutions Datasheet Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of quality test & measurement (T&M) equipment. We stock all major equipment types such as spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.

We are focused at the professional end of the marketplace, primarily working with customers for whom high performance, quality and service are key, whilst realising the cost savings that second user equipment offers. As such, we fully test & refurbish equipment in our in-house, traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2 year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of combined experience,which enables us to deliver industry-leading service and support. We endeavour to be customer focused in every way right down to the detail, such as offering free delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan unit, if available) and supplying a free business tool with every order.

As well as the headline benefit of cost saving, second user offers shorter lead times, higher reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and offers fast delivery, ?exibility, try-before-you-buy, zero capital expenditure, lower risk and off balance sheet accounting. Both second user and rental improve the key business measure of Return On Capital Employed.

We are based near Heathrow Airport in the UK from where we supply test equipment worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house Lab.

All products supplied by Test Equipment Solutions include:

- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).

- Free loan equipment during warranty repair, if available.

- Full electrical, mechanical and safety refurbishment in our in-house Lab.

- Certificate of Conformance (calibration available on request).

- Manuals and accessories required for normal operation.

- Free insured delivery to your UK mainland address (sales).

- Support from our team of seasoned Test & Measurement engineers.

- ISO9001 quality assurance.

Test equipment Solutions Ltd

Unit 8 Elder Way

Waterside Drive

Langley

Berkshire

SL3 6EP

T: +44 (0)1753 596000

F: +44 (0)1753 596001

Email: info@https://www.sodocs.net/doc/3016414804.html,

Web: https://www.sodocs.net/doc/3016414804.html,

Agilent N5700 Series

System DC Power Supplies

Models: N5741A-49A, N5750A-52A, N5761A-69A, N5770A-72A

Data Sheet

? 24 models: 750 W and 1500 W output power ? Up to 600 V and up to 180 A ? Small high density 1 U package

? Built-in voltage and current measurement ? Full protection from over-voltage and over-current ? 85-265 Vac universal AC input

? Command compatibility for Sorensen DLM and Xantrex XFR DC supplies ? LAN, USB, and GPIB interfaces standard ? Fully compliant to LXI Class C specification

?

Family of Affordable Basic System DC Power Supplies

The Agilent N5700 Series system DC power supplies give you just the right performance — at just the right price — in a compact (1 U) package. This family of affordable 750 W and 1500 W single-output programmable DC power supplies consists of 24 models for simple DC power applications. They provide stable output power, built-in voltage and current measurement, and out-put voltage and current from 6 V to 600 V and 1.3 A to 180 A.

These economical supplies offer many system-ready features like multiple standard I/O interfaces to simplify and accelerate test-system development for R&D, design valida-tion, and manufacturing engineers in the aerospace/defense, automotive, component and communications industries.

Small, high-density package saves you rack space

The N5700 provides up to 1500 W in a small space-saving 1 U-high, 19-inch-wide package. Its air vents are in the front, side and rear (not on the top or bottom), so you can stack other instruments directly above or below it to save valuable rack space.

2

Figure 1. Front-panel control knobs and buttons make it easy to use N5700 power supplies.

Figure 2. Built-in Ethernet, USB 2.0, and GPIB interfaces enable easy system connections.

Easy front-panel operation

You can quickly and easily operate the power supply with its rotary knobs and buttons. Using the front-panel controls, you can make coarse or fine adjustments of output voltage and current, protection settings, and set power-on states (last setting memory or factory default setting). The output voltage and current are displayed simultaneously, and LED indicators show power supply status and operating modes. You can lock the front panel controls to protect against accidental power-supply parameter changes.

Extensive device protection

To safeguard your device from damage, the N5700 Series power supplies provide over-temperature, over-current and over-voltage protec-tion (OVP) to shut down the power supply output when a fault condition occurs. They also offer an under-voltage limit (UVL) that prevents adjustment of the output voltage below a certain limit. The combina-tion of UVL and OVP capabilities lets you create a protection window for sensitive load circuitry.

Simplify system connections

The N5700 Series power supplies come standard with GPIB, Ethernet/LAN, and USB 2.0 interfaces giving you the flexibility to use your I/O interface of choice today and in the future. The N5700 is fully compliant with the LXI Class C specification.

Remote access and control The built-in Web server provides remote access and control of the instrument via a standard browser such as Microsoft? Internet Explorer. Using the Web browser, you can set up, monitor and operate the N5700 remotely.

Easy system integration and configuration

To simplify system development, the N5700 comes standard with IVI-COM drivers. The N5700 supports the easy-

to-use SCPI (Standard Commands for Programmable Instruments). Command compatibility

The N5700 includes a compatibility command set for the Xantrex XFR series power supplies, the Sorensen DLM series power supplies, and the Agilent 603x series power supplies. This simplifies system integration when converting to the N5700. For a comparison of these products, see application notes:

? S ide-by-side comparison:

Agilent N5700 Series System DC Source and Sorensen DLM DC Power Supply, AN 1502-1,

5989-1628EN

? S ide-by-side comparison: Agilent N5700 Series System DC Source and Xantrex XFR

AN 1502-2, 5989-1630EN Flexible configuration:

connect multiple units in

parallel and series

Should you need greater output power,

the N5700 series power supplies give

you the flexibility to connect in paral-

lel up to four similarly rated units for

greater output current and connect

two similarly rated units in series for

greater output voltage (see output

terminal isolation information).

Analog programming and

monitoring

The output voltage and current can

be programmed from zero to full scale

by either an analog voltage 0 to 5 V

or 0 to 10 V or by resistances of

0 to 5 k? or 0 to 10 k?.

Universal AC input

All N5700 models have universal AC

input so they can be automatically

operated from any AC mains input

voltage worldwide. They can be

operated from line voltages of

85 – 265 Vac, 47 to 63 Hz, with no

switch to set or fuses to change

when you switch from one voltage

standard to another. They also

provide power factor correction.

Rack mounting

The rack mount ears and handles

are provided standard with every unit.

In addition the N5740A rack mount

slide kit makes it easy to integrate an

N5700 into a test rack by providing

all the necessary hardware to rack

mount an N5700 series power supply

in only 1 U of rack space.

Figure 3. N5700 series web graphical user interface for remote access and control of the

power supply.

3

Performance specifications

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.

Current 25 mA23 mA17 mA12.6 mA

(change from 85-132 VAC input Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV Current 12 mA11 mA8 mA 5.8 mA

Voltage 0.05%+ 3 mV 4 mV 6.25 mV10 mV Current 0.1%+100 mA90 mA60 mA38 mA Voltage0.1%+ 6 mV8 mV12.5 mV20 mV Current0.1%+300 mA270 mA180 mA114 mA

Load transient recovery time4Time≤1.5 ms≤1.5 ms≤1.5 ms≤1 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical

performance determined either by design or type testing

(settle to within ±1.0% of the rated output, with a resistive Up, full load0.08 s0.08 s0.08 s0.08 s Down, full load0.05 s0.05 s0.05 s0.05 s Down, no load0.5 s0.6 s0.7 s0.8 s

55 ms

Remote sense compensation Volts/load lead 1 V 1 V 1 V 1 V

Range 0.5–7.5 V0.5–10 V1–15 V1–24 V

Accuracy 0.06 V0.08 V0.125 V0.20 V

CC rms 200 mA180 mA120 mA76 mA

Voltage0.72 mV0.96 mV 1.5 mV 2.4 mV

Current 12 mA10.8 mA7.2 mA 4.56 mA

Voltage 0.03 V0.04 V0.06 V0.10 V

Current 0.50 A0.45 A0.30 A0.19 A

Notes:

1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.

Minimum current is guaranteed to a maximum of 0.4% of the rated output current.

2 Up to 20 MHz

3 From 5 Hz – 1 MHz

4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.

Voltage set point from 10% to 100% of rated output

5 Add this to the output reponse time to obtain the total programming time

6 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)

4

Performance specifications

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.

Current 7.5 mA 6.9 mA 6.5 mA 6 mA

(change from 85-132 VAC input Voltage8 mV10 mV12 mV17 mV Current 3.25 mA 2.95 mA 2.75 mA 2.5 mA

Voltage 0.05%+30 mV40 mV50 mV75 mV Current 0.1%+12.5 mA9.5 mA7.5 mA 5 mA Voltage0.1%+60 mV80 mV100 mV150 mV Current0.1%+37.5 mA28.5 mA22.5 mA15 mA

Load transient recovery time4Time≤1 ms≤1 ms≤1 ms≤2 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical

performance determined either by design or type testing

(settle to within ±1.0% of the rated output, with a resistive Up, full load0.08 s0.15 s0.15 s0.15 s Down, full load0.08 s0.15 s0.15 s0.15 s Down, no load 1.1 s 1.2 s 1.5 s 2.0 s

55 ms

Remote sense compensation Volts/load lead 3 V 4 V 5 V 5 V

Range 5–66 V5–88 V5–110 V5–165 V

Accuracy 0.60 V0.80 V 1 V 1.5 V

CC rms 38 mA29 mA23 mA18 mA

Voltage7.2 mV9.6 mV12 mV18 mV

Current 1.5 mA 1.14 mA0.9 mA0.6 mA

Voltage 0.3 V0.4 V0.5 V0.75 V

Current 0.0625 A0.0475 A0.0375 A0.0250 A

Notes:

1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.

Minimum current is guaranteed to a maximum of 0.4% of the rated output current.

2 Up to 20 MHz

3 From 5 Hz – 1 MHz

4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.

Voltage set point from 10% to 100% of rated output

5 Add this to the output reponse time to obtain the total programming time

6 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)

5

Performance specifications

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.

Current41 mA38 mA29 mA20.2 mA

(change from 85-132 VAC input Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV Current20 mA18.5 mA14 mA9.6 mA

Voltage 0.05%+ 3 mV 4 mV 6.25 mV10 mV Current0.1%+180 mA165 mA120 mA76 mA Voltage0.1%+ 6 mV8 mV12.5 mV20 mV Current0.1%+540 mA495 mA360 mA228 mA

Load transient recovery time4Time≤1.5 ms≤1.5 ms≤1.5 ms≤1 ms Supplemental characteristics Supplemental characteristics are not warranted but are descriptions of typical

performance determined either by design or type testing.

(settle to within ±1.0% of the rated output, with a resistive Up, full load0.08 s0.08 s0.08 s0.08 s Down, full load0.05 s0.05 s0.05 s0.05 s Down, no load0.5 s0.6 s0.7 s0.8 s

55 ms

Remote sense compensation Volts/load lead 1 V 1 V 1 V 1 V

Range 0.5–7.5 V0.5–10 V1–15 V1–24 V

Accuracy0.06 V0.08 V0.125 V0.20 V

CC rms 360 mA330 mA240 mA152 mA

Voltage0.72 mV0.96 mV 1.5 mV 2.4 mV

Current 21.6 mA19.8 mA14.4 mA9.12 mA

Voltage 0.03 V0.04 V0.0625 V0.1 V

Current 0.90 A0.825 A0.60 A0.38 A

Notes:

1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.

Minimum current is guaranteed to a maximum of 0.4% of the rated output current.

2 Up to 20 MHz

3 From 5 Hz – 1 MHz

4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.

Voltage set point from 10% to 100% of rated output

5 Add this to the output reponse time to obtain the total programming time

6 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)

6

Performance specifications

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.

Current 10 mA8.8 mA8 mA7 mA

(change from 85-132 VAC input Voltage8 mV10 mV12 mV17 mV Current 4.5 mA 3.9 mA 3.5 mA 3 mA

Voltage 0.05%+30 mV40 mV50 mV75 mV Current 0.1%+25 mA19 mA15 mA10 mA Voltage0.1%+60 mV80 mV100 mV150 mV Current0.1%+75 mA57 mA45 mA30 mA

Load transient recovery time4Time≤1 ms≤1 ms≤1 ms≤2 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical

performance determined either by design or type testing

(settle to within ±1.0% of the rated output, with a resistive Up, full load0.08 s0.15 s0.15 s0.15 s Down, full load0.08 s0.15 s0.15 s0.15 s Down, no load 1.1 s 1.2 s 1.5 s 2.0 s

55 ms

Remote sense compensation Volts/load lead 3 V 4 V 5 V 5 V

Range 5–66 V5–88 V5–110 V5–165 V

Accuracy 0.60 V0.80 V 1 V 1.5 V

CC rms 75 mA57 mA45 mA35 mA

Voltage7.2 mV9.6 mV12 mV18 mV

Current 3 mA 2.28 mA 1.8 mA 1.2 mA

Voltage 0.3 V0.4 V0.5 V0.75 V

Current 0.125 A0.095 A0.075 A0.050 A

Notes:

1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.

Minimum current is guaranteed to a maximum of 0.4% of the rated output current.

2 Up to 20 MHz

3 From 5 Hz – 1 MHz

4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.

Voltage set point from 10% to 100% of rated output

5 Add this to the output reponse time to obtain the total programming time

6 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)

7

Series and parallel capability Parallel operation

Up to 4 units can be connected in master/slave mode

Series operation

Up to 2 units can be connected in series

Output terminal isolation

6 V to 60 V units

No output terminal may be more than ±60 VDC from any other terminal or chassis ground

80 V to 600 V units

No output terminal may be more than ±600 VDC from any other terminal or chassis ground

Store-recall states

Volatile memory locations: 16 Analog programming

(of output voltage and current)

Input signal

Selectable;

0 to 5 V / 0 to 10 V full scale

Input impedance

Selectable;

0 to 5 k? / 0 to 10 k? full scale Interface capabilities

GPIB

SCPI – 1993, IEEE 488.2 compliant interface

USB 2.0

Requires Agilent I/O library version L.01.01

10/100 LAN

Requires Agilent I/O library version L.01.01Web server

Built-in Web server requires Internet

Explorer 5+ or Netscape 6.2+

Environmental conditions

Environment

Indoor use, installation category II

(AC input), pollution degree 2

Operating temperature

0°C to 40°C @ 100% load

Storage temperature

–20°C to 70°C

Operating humidity

30% to 90% relative humidity

(no condensation)

Storage humidity

10% to 95% relative humidity

(no condensation)

Altitude

? Up to 3000 meters.

Derate the output current by

2%/100 m above 2000 m.

? Derate the maximum ambient

temperature by 1°C/100 m above

2000 m.

Regulatory compliance

EMC

? European EMC directive 89/336/

EEC for Class A products

? Australian C- Tick mark

? This ISM device complies with

Canadian ICES-001.

? Cet appareil ISM est conforme à la

norme NMB-001 du Canada.

Safety

? European Low Voltage Directive

73/23/EEC

? US and Canadian safety standards

? Any LEDs used in this product are

Class 1 as per IEC 825-1

Acoustic noise declaration

Emission directive:

? Sound pressure Lp <70 dB(A),

At operator position,

*Normal operation,

*According to EN 27779 (Type

Test).

? Schalldruckpegel Lp <70 dB(A)

*Am Arbeitsplatz, *Normaler

Betrieb, *Nach EN 27779

(Typprüfung).

AC input

Nominal input

100 – 240 VAC; 50/60 Hz

Input current 750 W

10.5 A @ 100 VAC nominal;

5 A @ 200 VAC nominal

Input current 1500 W

21 A @ 100 VAC nominal;

11 A @ 200 VAC nominal

Input range

85 – 265 VAC; 47 – 63 Hz.

Power factor

0.99 at nominal input and rated

output power

Efficiency

76% – 87% for 750 W units;

77% – 88% for 1500 W units

Inrush current

<25 A for 750 W units;

<50 A for 1500 W units

Dimensions

(excluding connectors, and handles)

Height 43.6 mm (1.72 in)

Width 422.8 mm (16.65 in)

Depth 432.8 mm (17.04 in)

Weight

750 W 7 Kg (15.4 lbs.)

1500 W 8.5 Kg (18.7 lbs.)

WARNING Shock Hazard

? F or models up to 60 VDC rated output, no point on the output shall be more than ± 60 VDC above or below chassis ground.? F or models greater than 60 VDC rated output, no point on the Positive output shall be more than ± 600 VDC above or below chassis ground.

? F or models greater than 60 VDC rated output, no point on the Negative output shall be more than ± 400 VDC above or below chassis ground.

Supplemental Characteristics for All Model Numbers

8

9

GPIB

ANALOG PROGRAMMING NOT ACTIVE AC INPUT

J1

TX

LINK

10/100 Ethernet

422.8 mm

+V –V

507.0 mm

433.0 mm

92.0 mm 92.0 mm

21.0 mm

A A

Outline Diagram

AC input

Strain-relief detail 1500 W models

39.5 mm

22.0 mm

3.0 mm

35.0 mm

Front and Rear Panel Detail

Front Panel

(All Models)

= air flow (in front, out rear) Rear Panel*

(6 V to 60 V, 1500 W Models)

(80 V to 600 V, 1500 W Models)

(6 V to 60 V, 750 W Models)

(80 V to 600 V, 750 W Models)

10

Ordering Information

Available models

System DC Power Supply 150 V, 5 A, 750 W

System DC Power Supply 300 V, 2.5 A, 750 W

System DC Power Supply600 V, 1.3 A, 780 W

System DC Power Supply 6 V, 180 A, 1080 W

System DC Power Supply 8 V, 165 A, 1320 W

System DC Power Supply 12.5 V, 120 A, 1500 W

System DC Power Supply 20 V, 76 A, 1520 W

System DC Power Supply 30 V, 50 A, 1500 W

System DC Power Supply 40 V, 38 A, 1520 W

System DC Power Supply 60 V, 25 A, 1500 W

System DC Power Supply 80 V, 19 A, 1520 W

System DC Power Supply 100 V, 15 A, 1500 W

System DC Power Supply 150 V, 10 A, 1500 W

System DC Power Supply 300 V, 5 A, 1500 W Options

750 W Models

Opt 900 Power Cord, United Kingdom Opt 902 Power Cord, Europe

Opt 903 Power Cord, USA, Canada Opt 918 Power Cord, Japan

Opt 922 Power Cord, China

1500 W Models

Opt 861 Unterminated Power Cord,

USA, Canada, Japan, China,

Other

Opt 862 Harmonized Unterminated

Power Cord, Europe Accessories

N5740A Rack Mount Slide Kit

(required for rack mounting;

standard system 11 rack-

mounting hardware will not

work)

Related Literature

These application notes will help you compare Agilent system DC sources with power supplies from other manufacturers:

? Side-by-Side Comparison: Agilent N5700 Series System DC Source and Sorensen DLM DC Power Supply, AN 1502-1, 5989-1628EN

https://www.sodocs.net/doc/3016414804.html,/

litweb/pdf/5989-1628EN.pdf

? How to Convert from a Sorensen DLM to an Agilent N5700,

AN 1503-1, 5989-1629EN

https://www.sodocs.net/doc/3016414804.html,/

litweb/pdf/5989-1629EN.pdf ? S ide-by-S ide Comparison:

Agilent N5700 Series System DC

Source and Xantrex XFR System

Power Supplies, AN 1502-2,

5989-1630EN

https://www.sodocs.net/doc/3016414804.html,/

litweb/pdf/5989-1630EN.pdf

? How to Convert from a Xantrex

XFR to an Agilent N5700,

AN 1503-2, 5989-1631EN

https://www.sodocs.net/doc/3016414804.html,/

litweb/pdf/5989-1631EN.pdf

? Trends in Medium Power (~1 kW)

DC Power Supplies, 5989-1331EN

https://www.sodocs.net/doc/3016414804.html,/

litweb/pdf/5989-1331EN.pdf

Agilent’s IO Libraries Suite ships

with the N5700 to help you quickly

establish an error-free connection

between your PC and instruments -

regardless of the vendor. It provides

robust instrument control and works

with the software development

environment you choose.

For additional description of Agilent’s

IO Libraries Suite features and instal-

lation requirements, please go to

https://www.sodocs.net/doc/3016414804.html,/find/iosuite-

datasheet

11

Agilent Email Updates

https://www.sodocs.net/doc/3016414804.html,/find/emailupdates Get the latest information on the products and applications you select. https://www.sodocs.net/doc/3016414804.html,

LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent

is a founding member of the LXI consortium.

Agilent Channel Partners

w w https://www.sodocs.net/doc/3016414804.html,/find/channelpartners Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience.For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: https://www.sodocs.net/doc/3016414804.html,/find/contactus Americas

Canada (877) 894 4414 Brazil (11) 4197 3500 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific

China 800 810 0189

Hong Kong 800 938 693

India 1 800 112 929

Japan 0120 (421) 345

Korea 080 769 0800

Malaysia 1 800 888 848

Singapore 1 800 375 8100

Taiwan 0800 047 866

Other AP Countries (65) 375 8100

Europe & Middle East

Belgium

Denmark 45 70 13 15 15

Finland 358 (0) 10 855 2100

France 0825 010 700*

*0.125

€/minute

Germany 49 (0) 7031 464 6333

Ireland 1890 924 204

Israel 972-3-9288-504/544

Italy 39 02 92 60 8484

Netherlands 31 (0) 20 547 2111

Spain 34 (91) 631 3300

Sweden 0200-88 22 55

United Kingdom 44 (0) 131 452 0200

For other unlisted countries:

https://www.sodocs.net/doc/3016414804.html,/find/contactus

Revised: June 8, 2011

Product specifications and descriptions

in this document subject to change

without notice.

? Agilent Technologies, Inc. 2011

Published in USA, August 22, 2011

5989-1330EN

https://www.sodocs.net/doc/3016414804.html,

https://www.sodocs.net/doc/3016414804.html,/find/

dcpowersupplies

Agilent Advantage Services is committed

to your success throughout your equip-

ment’s lifetime. To keep you competitive,

we continually invest in tools and

processes that speed up calibration and

repair and reduce your cost of ownership.

You can also use Infoline Web Services

to manage equipment and services more

effectively. By sharing our measurement

and service expertise, we help you create

the products that change our world.

https://www.sodocs.net/doc/3016414804.html,/quality

https://www.sodocs.net/doc/3016414804.html,/find/advantageservices

https://www.sodocs.net/doc/3016414804.html,

AdvancedTCA? Extensions for

Instrumentation and Test (AXIe) is

an open standard that extends the

AdvancedTCA for general purpose

and semiconductor test. Agilent

is a founding member of the AXIe

consortium.

https://www.sodocs.net/doc/3016414804.html,

PCI eXtensions for Instrumentation

(PXI) modular instrumentation

delivers a rugged, PC-based high-

performance measurement and

automation system.

Microsoft and Windows are U.S. registered

trademarks of Microsoft Corporation

For the latest and complete specifica-

tions, refer to the N5700 User’s Guide,

Agilent part number 5969-2917. The

web contains the most up-to-date

version of the User’s Guide. Go to

https://www.sodocs.net/doc/3016414804.html,/find/N5700

相关主题